Location and Mounting Requirements

Hardware Installation Guide

Mediatrix C7 Series – Digital Gateway

 

9

Wiring Requirements

Make sure that the telephone wiring, LAN and WAN cables reach the device and can be dressed in a manner 
that is safe for the wiring, does not pull or create lateral stress on the connectors on the device, and does not 
present a trip hazard to personnel working in the vicinity of the equipment. Do not connect any cable or wiring 
at this time.

Summary of Contents for Mediatrix C710

Page 1: ...Discover the Power of 5 Pb RoHS COMPLIANT 2002 95 EC Hardware Installation Guide Mediatrix C7 Series Product Version 2 0 Document Revision 02 March 27 2013...

Page 2: ...without the obligation to notify any person and or entity of such revisions and or changes Trademarks Microsoft and Windows are registered trademarks of Microsoft Corporation Adobe and Acrobat are re...

Page 3: ...Chapter 1 Overview 1 Overview 1 Key Features 1 Mediatrix C7 Series Connectors and Indicators 1 Product Serial Number Location 1 Front Indicators and Connectors 2 Rear Connectors 2 Chapter 2 Installat...

Page 4: ...8 At Start Time 19 Partial Reset 19 Factory Reset 19 Management Choices 20 Appendix A Standards Compliance and Safety Information 21 Standards Supported 21 Disclaimers 22 CE Marking 22 RoHS Declaratio...

Page 5: ...Hardware Installation Guide Mediatrix C7 Series v Appendix C Glossary 33 Appendix D List of Acronyms 37...

Page 6: ...Contents vi Mediatrix C7 Series...

Page 7: ...er s broadband access With FXO interfaces it is the ideal solution to deploy private or hosted toll bypass networks It provides a simple transparent and cost effective way of maintaining a connection...

Page 8: ...ling and configuring networking equipment and who are familiar with the Mediatrix C7 Series device Related Documentation In addition to this manual the Mediatrix C7 Series document set includes the fo...

Page 9: ...ge 5 Contains instructions for installing the Mediatrix C7 Series and connecting the cables Chapter 3 Powering on the Mediatrix C7 Series on page 13 Leads you through the basic steps to start the Medi...

Page 10: ...age circuit or packet switching and control devices The Public Switched Telephone Network PSTN or a Private Branch eXchange PBX are examples of SCNs Standards Supported When available this document li...

Page 11: ...tation Follow this link to register http www media5corp com en support portal Documentation Feedback Media5 welcomes your evaluation of this manual and any suggestions you may have These help us to im...

Page 12: ...Preface About this Manual End User Technical Support xii Mediatrix C7 Series Digital Gateway...

Page 13: ...switches enabling to establish two connections between conventional analog telephones or Group 3 fax machines and either a WAN a LAN or a personal computer Key Features IP connectivity for analog phon...

Page 14: ...2 shows the rear panel of the Mediatrix C7 Series Figure 2 Mediatrix C7 Series Rear Panel Connectors Table 3 Mediatrix C7 Series Front LEDs LED Description 1 Ready When lit the Mediatrix C7 Series is...

Page 15: ...t switch Resets configuration parameters of the Mediatrix C7 Series to default known values It can be used to reconfigure the unit Warning Read Section RESET DEFAULT Button on page 18 before attemptin...

Page 16: ...Chapter 1 Overview Mediatrix C7 Series Connectors and Indicators 4 Mediatrix C7 Series Digital Gateway...

Page 17: ...checklist and mark the entries as you complete each task Include the completed checklist in your site log Figure 3 Installation Checklist Mediatrix C7 Series name serial number _______________________...

Page 18: ...following network information Network Diagram It is always good practice to draw a network overview diagram that displays all neighbouring IP nodes serial connected elements and other components It is...

Page 19: ...ntial hazard to people or makes equipment unsafe Preventing Electrostatic Discharge Damage Wear an ESD preventive wrist strap ensuring that it makes good skin contact Connect the clip to earth ground...

Page 20: ...well ventilated location where it will not be exposed to high temperature or humidity Do not install the Mediatrix C7 Series in a location exposed to direct sunlight or near stoves or radiators Excess...

Page 21: ...that the telephone wiring LAN and WAN cables reach the device and can be dressed in a manner that is safe for the wiring does not pull or create lateral stress on the connectors on the device and doe...

Page 22: ...the Mediatrix C7 Series over the screws installed in the previous step 7 Proceed to Hardware Installation on page 11 Free Standing Unit When installing the Mediatrix C7 Series on a desk or table it sh...

Page 23: ...the ETH1 connector of the Mediatrix C7 Series connect the other end to a compatible Ethernet interface that supplies TCP IP network access e g router switch hub or computer Use a standard telecommunic...

Page 24: ...eway Use a standard telecommunication cord with a minimum of 26 AWG wire size You can either use a crossover or straight Ethernet cable because it performs automatic MDI MDIX detection See RJ 45 Cable...

Page 25: ...ocated on the bottom side of the unit It is stored in the System Information page of the web interface P address you can discover which IP address has been assigned to the Mediatrix C7 Series by eithe...

Page 26: ...P address DNS IP addresses Configuration script server IP address and port number optional SIP Servers IP address and port number 3 The Mediatrix C7 Series request its configuration by using a configu...

Page 27: ...etween 7 11 seconds This procedure is called a partial reset After a partial reset is performed the Mediatrix C7 Series enables its link local IPv6 address Refer to Partial Reset on page 19 for detail...

Page 28: ...D Patterns Specific Conditions Table 6 describes the different states a Mediatrix unit can have and their associated LED patterns 1 MAC address of the Mediatrix C7 Series Table 5 Vocal Unit Informatio...

Page 29: ...red when the unit is booting on the recovery bank and no update is pending Power LED blinking 0 25Hz 75 duty Automatic network configuration in progress Waiting for DHCP IPv4 or IPv6 answer or IPv6 ro...

Page 30: ...teady ON All lines are disabled operational state Steady OFF At least one line is enabled and at least one line is disabled operational state Blink 0 25 Hz 75 Table 7 Default LED Behaviour Continued L...

Page 31: ...ets the serverPort to its default value To trigger the Partial Reset 1 Insert a small unbent paper clip into the RESET DEFAULT hole located at the rear of the Mediatrix C7 Series While pressing the RE...

Page 32: ...hoices Congratulations for properly installing the Mediatrix C7 Series You can now configure the software parameters of the unit The Mediatrix C7 Series offers various management options All these opt...

Page 33: ...2007 03 27 CAN CSA C22 2 No 60950 1 07 2nd Edition 2007 IEC 60950 1 2005 2nd Edition with all national deviations Emissions EN61000 3 2 1995 Harmonic current emissions EN61000 3 3 1995 Voltage fluctua...

Page 34: ...the presumption of conformity with the applicable essential requirements of DIRECTIVE 1999 5 EC OF THE EUROPEAN PARLIAMENT RTTE DIRECTIVE is given Any unauthorized modification of the product voids th...

Page 35: ...Disclaimers Hardware Installation Guide Mediatrix C7 Series Digital Gateway 23 RoHS China...

Page 36: ...tandards Compliance and Safety Information Disclaimers 24 Mediatrix C7 Series Digital Gateway Altitude of Operation Translated from Chinese as Used only at altitudes not more than 2000m above sea leve...

Page 37: ...ur Vermeidung von Unf llen bewu t Avvertenza Questo simbolo di avvertenza indica un pericolo La situazione potrebbe causare infortuni alle persone Prima di lavorare su qualsiasi apparecchiatura occorr...

Page 38: ...fety Warnings 26 Mediatrix C7 Series Digital Gateway Safety Warnings This section lists the following safety warnings Circuit Breaker 15A Warning TN Power Warning Product Disposal Warning No 26 AWG Wa...

Page 39: ...TN power systems Warning Ultimate disposal of this product should be handled according to all national laws and regulations Warning To reduce the risk of fire use only No 26 AWG or larger telecommunic...

Page 40: ...k of fire electric shock and injury to persons including the following Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a...

Page 41: ...6 AWG wire size It is possible to use either a crossover or straight Ethernet cable to connect in the Ethernet connectors These connectors perform automatic MDI MDIX detection meaning that they adapt...

Page 42: ...solid orange 3 Receive White with orange stripe White with green stripe 4 N A Blue with white stripe or solid blue Blue with white stripe or solid blue 5 N A White with blue stripe White with blue str...

Page 43: ...eliminates the need for a hub when connecting two computers A crossover cable may also be required when connecting a hub to a hub or a transceiver to transceiver or repeater to repeater When connectin...

Page 44: ...J 11 connectors in a specific orientation The following figure illustrates how the pins on the RJ 11 connector are numbered Be sure to hold the connectors in the same orientation when attaching the wi...

Page 45: ...l DHCP TCP IP protocol that enables PCs and workstations to get temporary or permanent IP addresses out of a pool from centrally administered servers Federal Communications Commission FCC U S governme...

Page 46: ...over analog telephone lines Router A specialized switching device which allows customers to link different geographically dispersed local area networks and computer systems This is achieved even thou...

Page 47: ...Mediatrix C7 Series Digital Gateway 35 Wide Area Network WAN A large geographically dispersed network usually constructed with serial lines that covers a large geographic area A WAN connects LANs usin...

Page 48: ...Appendix C Glossary Wide Area Network WAN 36 Mediatrix C7 Series Digital Gateway...

Page 49: ...ering Task Force LAN Local Area Network MAC Media Access Control MDI Media Dependent Interface MDIX Media Dependent Interface Crossover PBX Private Branch eXchange PSTN Public Switched Telephone Netwo...

Page 50: ...Appendix D List of Acronyms 38 Mediatrix C7 Series...

Page 51: ...b site xi where to obtain xi E end user technical support xi F factory reset reverting to 19 see also partial reset Foreign Exchange Service Station FXS defined 33 see also lines front connectors 2 in...

Page 52: ...and FXS Connectors 27 No 26 AWG 27 Product Disposal 27 Socket Outlet 27 TN Power 27 site selecting for unit 8 special vocal features IP address 15 MAC address 16 standards compliance agency approvals...