Chapter 10 - Operation Section
Medha Servo Drives Pvt Ltd.
42
1. CIRCUIT BREAKER PANELS
a. The following Circuit Breakers must be ON for Locomotive running:
Ÿ
AC CONTROL
Ÿ
CONTROL
Ÿ
LOCAL CONTROL
Ÿ
AUX.GEN.FLD
Ÿ
FUEL PUMP
Ÿ
COMP.CONTROL
Ÿ
MICRO AIR BRAKE
Ÿ
DCL 1 TO DCL 6 (ALL SIX BREAKERS)
Ÿ
TC 1 COMPTR to TC 6 COMPTR (ALL SIX BREAKERS)
Ÿ
GEN. FIELD
Ÿ
TCC BLW 1 to TCC BLW 6 (ALL SIX BREAKERS)
b. The other Circuit Breaker should be ON as required:
Ÿ
LIGHTS
Ÿ
HEAD LIGHTS
Ÿ
CAB FANS
Ÿ
AIR DRYER
Ÿ
FILTER BLOWER MTR
c. At Circuit Breaker Panel verify that GROUND RELAY CUTOUT
switch is closed (lever up) and sealed.
ENGINE CONTROL PANEL:
1. ISOLATION switch in START/STOP/ISOLATE position.
2. Miscellaneous switches set as required.
CONTROL CONSOLES:
Set control console devices as follows:
1. Set CONTROL & FP switch ON (slider up). This always Fuel Pump
to start and Run when FP/ES switch is in Fuel Prime or Engine start.
2. Set Engine Run switch and the Gen. Field switch OFF (slider down
during cranking)
3. Set Light switches and other switches as desired.
4. Set Throttle Handle in IDLE. Center Reverser (neutral) and remove
it.
Electrical control cabinet must be securely closed during
Locomotive operation for proper cooling.
N
O
T
E