background image

13/12/2017 

Warranty

 

AGDS-2 

Medem (UK) Limited 

Project House  

19 Dallimore Road 

Manchester  

M23 9NX 

 

Tel: (0) 161 233 0600 

Fax: (0) 161 233 0601 

Web: www.medem.co.uk 

E-mail: [email protected] 

Medem UK Warranty 

Terms & Conditions 

 

1. 

The warranty is a parts warranty and Medem UK Ltd will not cover or accept any labour or 
other expenses that may be incurred in the process of changing faulty product. 

 
2. 

All panels and sender units are covered by a five year warranty. 

 
3. 

Gas detector units and other remote detectors carry a two year warranty. Installation of the 
detectors should not be undertaken until all building and construction work is completed. 

 
4. 

Gas solenoid valves carry the original manufacturers warranty, though as the supplier 
Medem UK will exchange faulty valves for return to the manufacturer. 

 
5. 

Where a Medem UK engineer (or another company appointed by Medem UK) commission 
and installed system then that system will carry a ten year warranty. This applies to the 
main panel and the sender unit. At the time of commissioning a security label with a serial 
number will be attached to the main panel box. photographs and a comprehensive record 
of the installation will be held by Medem UK. 

 
6. 

Where a warranty claim is made then, where appropriate, a written order to attend site 
must be provided to Medem UK A cost for labour and travel to site will be prepared as a 
quote. The cost must be included in the order. 

 

7. 

Where it is found that the installation and/or the quality of workmanship has contributed to 
or wholly caused the failure of the product then we reserve the right to charge the whole or 
a proportion of the cost of the faulty item.

 

Summary of Contents for AGDS-2

Page 1: ...alled and commissioned to the satisfaction of the manufacturer A commissioning certificate must be issued to the end user along with instructions for the operation of the equipment As the Manufacturer...

Page 2: ...gh alarm Carbon Monoxide detectors are pre calibrated at 80ppm pre alarm and 100ppm for high alarm Connect a detector to either the detector 1 terminals 6 7 or detector 2 terminals 8 9 each detector h...

Page 3: ...connection Reset 12 Enable Detectors Channels enable a channel when it has a detector connected 13 High alarm time delay function Controls the length of time between a High alarm and the closing of th...

Page 4: ...be followed with reference to running low and mains voltage cables together The maximum cable length between a detector and the control panel should not exceed 100 metres if the distance between the...

Page 5: ...ould be wired in series with the EM stop buttons To EM Stop connections in the panel Indicator bar shows when pressed Normal EM Stop Activated Multiple Stop Buttons Single Stop Buttons Resetting indic...

Page 6: ...s that is being monitored for See the gas detectors own instructions for more guidance AGDS 2 Detector Information VE supply Comm s From either the main panel Address Selector The selector must be set...

Page 7: ...ng head height and between 1m and 3m from the potential source Care should be taken so they are not located close to the edge of a canopy or in direct flow of the supply or extract ventilation For add...

Page 8: ...lier Medem UK will exchange faulty valves for return to the manufacturer 5 Where a Medem UK engineer or another company appointed by Medem UK commission and installed system then that system will carr...

Page 9: ...ector 1 or detector 2 on the panel 5 Enable the detector channels 1 or 2 as being used by with switch 12 Connect the 3 amp fused spur 240 volt supply to marked terminals 6 Once power is connected to t...

Reviews: