background image

12/03

© MEDC 2002

1.

INTRODUCTION

This range of light weight all GRP, flameproof sounders intended for use in
potentially explosive atmospheres has been designed with high ingress protection
to cope with the harsh environmental conditions found offshore and onshore in
the oil, gas and petrochemical industries.

The flamepaths, flare and the body, are manufactured completely from UV stable
glass reinforced polyester. Stainless steel screws and sinter are incorporated thus
ensuring a corrosion free product. A tapered flamepath is used to overcome the
problems of assembly of parallel spigot flamepaths.

An optional Exe terminal chamber is available.

An uncertified version is available for use in non-explosive atmospheres.

2.

INSTALLATION

General

When installing and operating explosion-protected equipment, requirements for
selection, installation and operation should be referred to e.g. IEE Wiring
Regulations and the ‘National Electrical Code’ in North America. Additional
national and/or local requirements may apply.

Ensure that all nuts, bolts and fixings are secure.

Ensure that only the correct listed or certified stopping plugs are used to blank off
unused gland entry points and that the NEMA/IP rating of the unit is maintained.

The unit is mounted via 2 x Ø9mm (Ø0.35”) fixing holes in the ‘u’ shaped
stirrup/mounting bracket.

If required, the unit can be initially placed via the Ø13mm (Ø0.51”) central hole
in the stirrup. The unit can be rotated to the required position and fixed via the
two other holes.

The fixing holes accept M8 screws or bolts. MEDC recommend the use of the
following stainless steel screws.

The elevation of the unit can be adjusted by loosening the 2 x M6 screws which
fasten the stirrup to the horn. The unit can then be adjusted by rotating to the
required position and then tightening the M6 screws. The unit should be
positioned such that debris, dust or water cannot settle in the re-entrant horn.

Summary of Contents for DB3V

Page 1: ...been taken to ensure the accuracy of our technical manual We do not however accept responsibility for damage loss or expense resulting from any error or omission We reserve the right to make alterati...

Page 2: ...should be referred to e g IEE Wiring Regulations and the National Electrical Code in North America Additional national and or local requirements may apply Ensure that all nuts bolts and fixings are se...

Page 3: ...t least 5mm EExd EExde units Cable termination should be in accordance with specifications applying to the required application MEDC recommends that all cables and cores should be correctly identified...

Page 4: ...number two of SW1 back to the OFF position To re record the message press and hold the Red record button and playback the audio source as before The previous message will be recorded over 3 2 NORMAL...

Page 5: ...ccident etc then visual inspection is recommended If the unit requires cleaning then only clean exterior with a damp cloth to avoid electro static charge build up Painting and other surface finishes o...

Page 6: ...to 45 C T5 DB3LE 55 C to 55 C T5 The ATEX certificate and the product carry the ATEX group and category marking II 2 GD Where signifies compliance with ATEX II signifies suitability for use in surface...

Page 7: ...MEDC 2002 12 03...

Page 8: ...liery Road Pinxton Nottingham NG16 6JF UK Tel 44 0 1773 864100 Fax 44 0 1773 582800 Sales Enq Fax 44 0 1773 582830 Sales Orders Fax 44 0 1773 582832 MEDC Stock No E mail sales medc com Web www medc co...

Reviews: