© MEDC 2002
04/02
speaker and integrated with the unit such that this rating is maintained.
The internal earth terminal, where fitted, must be used for the equipment
grounding connection and the external terminal is for a supplementary
bonding connection where local codes or authorities permit or require
such a connection.
Once termination is complete, carefully push the cover assembly back
onto the base, avoiding damage to the mating surfaces.
Please Note:
The
cover should be fitted in the orientation as supplied by MEDC to avoid the
cover fouling on the internal components. Replace the 2 off screws into the
holes in the cover assembly and tighten evenly.
3. OPERATION
The operating voltage of the unit is stated on the unit label.
The speaker is available as a 15W version only.
Different sound levels can be obtained by selecting the transformer tap-
pings in the unit (see table below)
TRANSFORMER
POWER
TAPPINGS
15W
1:2
15
2:3
7.5
3:4
5
1:3
4
2:4
2
1:4
0.8
4. MAINTENANCE
During the working life of the unit, it should require little or no mainte-
nance. However, if abnormal or unusual environmental conditions occur
due to plant damage or accident etc., then visual inspection is recom-
mended.
If a unit fault should occur, then the unit can be repaired by MEDC. All
parts of the unit are replaceable.