background image

HMI - Operator panel: TP1043 02                                                                 Mect srl  

ME7056_11    07/21 

2.2 Mechanical dimensions 

In the following figures see the TP1043 dimensions. 

 

Panel with frame mounting and hooks fastening: 

Encumbrance

 

 

 

 

 

    
               Front view 

 

 

    

                 

           Side view 

 

 
Mounting plate 
 

 

 
 
 
 
 
 
 
 

Summary of Contents for TP1043 02 series

Page 1: ...ME7056_11 07 21 USER S MANUAL TP1043 02 series HMI Operator panel ...

Page 2: ......

Page 3: ...fication 4 2 2 Mechanical dimensions 5 2 3 Panel mount 8 2 3 1 Distance 8 2 4 TP1043 02 wiring 9 2 5 Connections 9 2 6 Power supply 10 2 6 1 System power supply 10 2 6 2 Fuse 10 2 7 ModBus wiring 11 2 8 CANOpen wiring 12 3 Peripherals 13 3 1 USB 13 3 2 Ethernet 13 3 3 Micro SD Card 13 3 4 Configuration DIP switches 13 3 5 UART debug 14 4 HMI PLC 15 4 1 System variables 15 5 How to order 16 ...

Page 4: ...by incorrect use of MECT devices due to noncompliance to this manual information MECT S r l has an help desk 1 2 Simbols Danger Follow this advice to avoid people injury Warning Follow this advice to protect the device Caution Follow this advice to have a more effective performance ESD Electrostatic discharge Danger possibly damage due to Electrostatic discharge Note Step to follow for a correct i...

Page 5: ...eck the power supply value on the instrument label Keep the power supply line as short as possible and keep it separate from other power lines For safety reasons it is necessary to have a 2 section power switch with a fuse near the instrument easily replaceable Avoid the presence of other power actuators in the same control panel high humidity excessive heat and corrosive gas Instruments must have...

Page 6: ... GPRS UMTS or Wi Fi key optionally sold by Mect is possible to connect the operator panel to a Wi Fi or Mobile network Settings under MENU OPTIONS NETWORK_CFG tab Wi Fi or tab Mobile On TP1043 02 there are up to 1 Kbyte for retentive variables stored on the internal flash memory The device is also able to manage an up to 64GB wide micro SD card The SD card is factory mounted on request A real time...

Page 7: ...istive 4 wires Ethernet 10Mbit s 100Mbit s self recognition Micro USB Host 2 0 Micro SD Max 64GB Software characteristics OS LINUX 2 35 PLC IEC61131 3 Graphics Based on QT library CAN CanOpen 2 0 ModBus Modbus RTU master Storage memory Possibility of history storage Field bus main features RTU Modbus Master 2 wires TCP Modbus Client Power supply Power Supply 24Vac Vdc 12 36Vdc 150mA 24Vdc 24Vac 20...

Page 8: ... panel TP1043 02 Mect srl ME7056_11 07 21 5 2 2 Mechanical dimensions In the following figures see the TP1043 dimensions Panel with frame mounting and hooks fastening Encumbrance Front view Side view Mounting plate ...

Page 9: ...HMI Operator panel TP1043 02 Mect srl ME7056_11 07 21 6 Panel with frame mounting and screws fastening Encumbrance Front view Side view Mounting plate ...

Page 10: ...n Table 2 Mechanical Material ABS Polycarbonate Dimensions W x L x H 27 mm x 156 mm x 80 mm Mounting plate 127mm x 68mm Installation Panel installation Environmental conditions Operative temperature 0 C 55 C Storage Temperature 20 C 85 C Relative Humidity 5 a 95 no condensation Electric isolation Air clearance According to IEC 60664 1 Pollution According to IEC 61131 2 2 Protection Rear protection...

Page 11: ... 2 3Panel mount 2 3 1 Distance The device must be installed with some space between other devices to allow the right dissipation and cabling In order to avoid EMC issues you should not overlap cables Figure 6A Horizontal mounting Figure 6B Vertical mounting ...

Page 12: ...ring 2 5 Connections In the following figure see the wiring diagram Figure 7 Table 3 TP1043 02 Power Supply 24Vdc Vac 12 36Vdc 150mA 24Vdc or 24Vac 20 150mA Micro USB 2 0 Ethernet Bit rate 100Mbit sec Serial ouputs RS485 Modbus half duplex hardware configuration or CANopen ...

Page 13: ...c or 24Vac see the model purchased according to the scheme in the figure System is protected against reverse power supply 2 6 2 Fuse The device has no internal fuse protection so the use of an external 500mA fuse for the panel power supply is recommended Figure 8 Attention A wrong power supply voltage can damage the device ...

Page 14: ... 7ModBus wiring ModBus on TP1043 02 is a 2 wire RS485 serial line at the following pins of the terminal board Table 4 Pin Signal Description 3 GNDiso GND 2 D Linea 1 D Linea Example of wiring for a system composed by MPNC006 MPNC020 MPNC030 TP1043 02 Figure 9 ...

Page 15: ...NOpen wiring The CANopen interface on TP1043 02 must be connected to the terminal block on the pins shown in the table Table 5 Pin Signal Description 3 GNDiso 2 CAN H Line 1 CAN L Line Example of wiring for a system composed by MPNC010 MPNC030 TP1043 02 Figure 10 ...

Page 16: ...2 has a 10 100Mbit s ethernet port with auto configuration the connection cable between TP1043 02 and a personal computer can be either straight either cross 3 3 Micro SD Card On TP1043 02 is it possible to insert a micro SD card up to 64 GB used by applications and or data logging The memory will be handled automatically by the device itself 3 4Configuration DIP switches In the rear of the panel ...

Page 17: ...e Note OFF OFF Internal Flash default Default configuration OFF ON USB Factory firmware upgrade do not use ON ON SD card ON OFF SD card 3 5UART debug In the bottom side of the rear panel there is a six pole header used for debug purpose The port is a TTL UART with the following pinout A commercial adapter is available from FTDI TTL 232R ...

Page 18: ...ice is programmed by a development suite Mect Suite QT based tailored to MECT products A tutorial specifically made for the device is available The Mect suite software run on Windows operative system 4 1System variables The system can use 5472 interchange variables between HMI and automation at maximum which include internal variables interchange variables on Modbus network retentive variables The...

Page 19: ...HMI Operator panel TP1043 02 Mect srl ME7056_11 07 21 16 5 How to order ...

Reviews: