19
disconnected at usual time). Turning switch can be used as the coin
mech switch when the game is power on.
4): Adjust the adjusting switch of COIN Signalwave length to 50MS.
5): Adjust the micro-adjusting resistance of token tolerance. Clockwise:
increasing the sensitivity of token tolerence, that is, the range of
accepting the token tolerance will be larger.Counterclockwise:
decrease the sensitivity, that is, the range will be smaller and choose
the token more strictly.
9.2
MAIN
BOARD
ADJUSTMENT
Diagram of main board:
Descriptions:
Enulling Button: pressing this button can set the Game Setting to default
and clear the data of Coin and Ticket saved in PCB.
Volume Adjustment: Use a flat screwdriver to twist the volume
potentiometer to adjust the volume level of the machine. Turning clockwise
will increase the volume; counterclockwise will decrease the volume.