2.
The connections to the hand held test system are sealed with ‘O’ ring, bonded seals
& Nylon washer to avoid leak.
Ensure that the adapters are tightened sufficiently.
Allow the pressure to settle for 1-2 minutes before taking the reading due to
thermodynamic effect, setting of seals and expansion of flexible hose.
3.
Red line indicator
The Fine adjustment should not be forced to move beyond the red
line indicator on the body
2.2 TECHNICAL SPECIFICATIONS
Pressure Medium
:
Air
Working Pressure
:
-0.90 to 10/20/25/35/40/60
Vernier Adjuster
:
Micro-adjustable, Volume control
Minimum resolution of Vernier
:
1 mbar
Test connection port
:
1/4” BSP (F)
Gauge/ Indicator connection port
:
3/8” BSP (F)
Weight
:
750 grams (appox.)
Stabilization time
:
1
– 2 minutes
Dimension
:
230 x 65 x 130 mm (L x B x W)
Summary of Contents for PHP-10