Drwg. No.
4896
GB
VIMARI 2316
- removable
1
Socket
cover
Post
Ground socket
Socket cover
OVERALL DIMENSIONS
l'apricance
llo
FADINI
l'apricance
llo
FADINI
160
214
103
Ø 250
Ø 250
Ø 220
Ø 200
thickness 4 mm
2
3
4
INSTRUCTIONS
VIMARI 2316
500 mm
[800]
l'apricance
llo
FADINI
l'apricance
llo
FADINI
Removal of the bollard:
- Insert the specially shaped spanner into the lock under the bollard cover.
- To
unlock
and remove the bollard, turn the spanner
clockwise
and lift the bollard out of the socket.
- Let the bollard stand and
remove the spanner
by turning it
anti-clockwise
.
- Cover the socket by means of the
lid
provided with the equipment.
Setting the bollard back:
carry out the previous operations in the reverse sequence: insert the spanner, turn it
clockwise
and put the bollard back into the
socket, then
lock it
in position and
remove the spanner
by turning it
anti-clockwise
.
UNLOCKING OPERATIONS AND REMOVAL OF THE BOLLARD
Slot to lock
the bollard into the socket
Bollard finish
RAL 7016 anthracite grey
Bollard weight
18 kg [500 mm]
Bollard weight
26 kg [800 mm]
Ground socket weight
9 kg
Cover
weight
3
kg
Bollard weight with ground socket
27 kg [500 mm]
Bollard weight with ground socket
35 kg [800 mm]
Impact resistance
[A]
30.000
J
Breakout resistance
[A]
150.000
J
[A] Various factors, such as the compaction index, soil permeability coefficient and kind
of concrete may reduce the values indicated even significantly.