background image

MOUNTING THE MAGNETIC LIMIT SWITCH BRACKETS

NOTE WELL: DO NOT OPEN THE BRACKETS TO REVERSE THE ARRAY OF THE INNER MAGNETS; THEY ARE 
PROPERLY PRE-ARRANGED FOR THE LOGIC CONTROL BOARD TO IDENTIFY THEM.

!

NOTE WELL: IT IS FUNDAMENTAL THAT THE GATE DOES NOT RUN INTO THE GATE STOPS TOO FAST ON 
OPENING AND CLOSING CYCLES; A 30-50 mm CLEARANCE SHOULD BE RECOMMENDED BEFORE THE 
LIMIT SWITCHES ARE ENGAGED.

!

electromechanical operator for sliding gates

Nyota 115 evo

 5 mm

Pic. 11

Pic. 12

!

!

Limit switch

right-hand

 

DX bracket

Limit switch

left-hand

 

SX bracket 

Open 

gate stop

Close
gate stop

30 - 50 mm

E

n

g

li

sh

!

30 - 50 mm

17

Summary of Contents for Nyota 115 evo 1-phase 0,5 HP

Page 1: ...lectromechanical operator for sliding gates up to 1 250 kg 0 5 HP version 1 850 kg 1 0 HP version EN 13241 EN 12453 EN 12445 GB Instructions manual pages 11 20 the gate opener 11 MAGNETIC LIMIT SWITCH...

Page 2: ...ing off the master switch If removing the actuator do not cut the electric wires but disconnect them from the terminal box by loosening the screws inside the junction box INSTALLATION All installation...

Page 3: ...he functioning of the Nyota 115 evo gate operator made in It aly www fadini net installatore Data Modello N serie CANCELLO AUTOMATICO l apricancello Position Description Type of electric cable MIRI 4...

Page 4: ...concrete has firmly set all around the the bracket Nyota 115 evo can be mounted onto it Cover removing unscrew the fastening screw completely Pic 4 then pull at the bottom in order to remove the cover...

Page 5: ...system is engaged Fix the gear rack modules all along the gate to coincide with the actually required gate travel By means of a spirit level make sure they are well aligned and take also into account...

Page 6: ...by Elpro 12 evo electronic control board depending on which model has been purchased NOTE WELL the Nyota 115 evo models that are not equipped with either the encoder or the Elpro 12 evo electronic co...

Page 7: ...TEWELL IT IS FUNDAMENTALTHATTHE GATE DOES NOT RUN INTOTHE GATE STOPSTOO FAST ON OPENING AND CLOSING CYCLES A 30 50 mm CLEARANCE SHOULD BE RECOMMENDED BEFORE THE LIMIT SWITCHES ARE ENGAGED electromecha...

Page 8: ...ory pre wired as if it were going to be installed on the left In case Nyota Evo is required to be installed on the left swap the connections to terminals 8 10 and 16 18 Magnetic limit switch sensor Ny...

Page 9: ...model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including...

Page 10: ...tomatically operated and remove any possible friction points 80 Nm 1 32 10 m 1 25 C 80 C IP 55 20 kg 1 800 kg very intensive FADINI OIL code 706L 80 Nm 1 32 10 m 1 25 C 80 C IP 55 19 5 kg 1 850 kg ver...