Mec TRITASK-300F Series Instruction Manual Download Page 2

 

Instruction Manual

 

TRITASK-300F Series

 

Version: May 2020

 

- 2 -

 

Mainland Energy Conversion Ltd.       

Tel:  +

852  2366  9610 

    E-mail

[email protected]

 

           

www.mec-powersolutions.com

 

 

Preparation 

– Before Charging

 

 

General Checking 

 

Check thoroughly the charger itself including all the cables show no damages 

 

Take into consideration the charging instruction issued by the battery manufacturer   

 

Charging Cable – Polarity Checking 

WARNING: Check the polarity before mounting onto a plug: 
 

 

Red cable = Plus (+) 

 

Black cable = Minus (-) 

 
DC Mains Supply Checking 

 

Make sure the DC cable must not be cut, shortened or extended under any circumstances 

 

Make sure the mains supply complies with the technical specification requirements of the charger 

 

Before Connecting the Charger to the Battery 

 

Make sure the charger is switched off and disconnected from the mains supply 

 

Then connect the terminals of the charger to the battery (Red cable to the positive (+) terminal of the battery; then Black cable to the negative 
(-) terminal) 

 

If the battery is built-in within a vehicle, the Black cable can be connected to the negative (-) terminal of the battery or the body of the vehicle; 
make sure the connection is done with a safe distance from the fuel line and take into consideration of the battery and vehicle manufacturer 

 

Finally connect the power cable of the charger to the mains supply, and switch on the charger 

 
 

Charging the Battery

 

 
Plug in and switch on the charger. The charging process starts automatically and runs through the following stages: 
 

Phase 1: Constant Current Charging 

Red Charge LED (7) blinks or lights up. The battery is being charged to 80% of its capacity at this stage. 
 

Phase 2: Constant Voltage Charging 

Yellow Charge LED (6) blinks or lights up. The battery is being charged to its maximum capacity. When the Green Full LED (5) turns on, the charger 
can now be disconnected from the battery. 
 

Phase 3: Float Charging 

Green Full LED (5) keeps on lighting indicate the battery has reached its full capacity. If the battery keeps connecting to the charger, float charge 
mode takes place to keep the readiness of the battery at all time. 
 

Disconnect the Charger from the Battery: 

 
1. 

First, disconnect the charger from the mains supply 

2. 

Then, disconnect the charger from the battery (disconnect the Black (-) cable first then the Red (+) cable) 

 
After disconnecting the charger from the mains, please wait at least 5 seconds  to reactivate the charger if in need – otherwise damages may be 
resulted. 
 
 

Charging Advice and Battery Care

 

 

Charging Advice: 

 

 

If the charger must be disconnected from the battery during the charging process, please FIRST disconnect the charger from the mains supply. 
The continuation of the charging process is equal to a new charging cycle; all relevant points of the Operating Instructions have to be considered. 

 

To lengthen the lifetime of the battery, please do not stop the charging process before the battery is fully charged. The charger will automatically 
switch to float charging when the charging process is completed.   

Battery Care: 

 

 

Never expose the battery to high temperatures, as this causes permanent battery capacity loss.   

 

Never deep-discharge or overcharge the battery, cells can be damaged irreversibly.   

 

If possible, always disconnect the battery from the load when being stored over long period of time.   

 

Store battery in a dry and cool place at about 40-60% of its rated capacity. 

 
 
 
 
 
 
 
 
 
 