5.6. 

Forming 

If  one  or  more  deep  discharged  batteries  are  inserted,  the  AV4m  automatically  tries  to  reach  the  required  cell 
voltage via forming. Therefore the battery is reactivated by regulated current pulses.  
This  process  is  indicated  in  the  display  by  showing 

For

“. If the forming succeeds a complete charging cycle is 

started  automatically.  If  the  forming  has  no  success  and  the  cell  cannot  be  reactivated  (max.  30  minutes),  no 
charging cycle will be started and 

Err

“ is shown in the display. 

 

Following errors are shown for the particular charging bay if applicable: 

Err 

= Battery defective, cell could not be reactivated 

bAd 

= Internal resistance is too high, cell is dried up 

In both cases the battery is damaged, therefore no more suitable and must be disposed professionally. 

 

6.  Errors and Troubleshooting 

1. No indication on the display: 

-Check if power supply or adapter is plugged-in in a proper way; 

 

-Check if the cable at the charger is plugged-in in a proper way; 

 

-Check if the cable is defective; 

2. Charging does not start: 

-Check if the battery is inserted reverse-poled; 

3. Charging abort: 

-Remove batteries and disconnect the charger for a short time; 

4. 

“Err“ shown in display: 

-Battery deep discharged (defective) 

 dispose according to regulations; 

5. 

“bAd“ shown in display: 

-Battery dried up (defective) 

 dispose according to regulations; 

 

7.  Technical Data 

 

 

8.  Disclaimer of Warranty 

  MEC-Energietechnik GmbH guarantees replacement or repair of chargers that are recognized as defective 

within 2 years under common environmental conditions. The validation of the warranty time starts with the de-
livery date from the manufacturer. MEC-Energietechnik GmbH is limiting the free guaranteeing to working hours 
and spare parts only. 

  For damages caused by non-observance of the operating instructions, inappropriate start up or handling as well 

as reconstructions and modifications of the device, the warranty claim expires and MEC-Energietechnik GmbH 
assumes no liability for consequential damage to property or persons! 

 

Repair work must only be accomplished by authorized companies or professional staff! 

 

9.  Advice for Disposal 

 

 

It is prohibited to dispose the charger into the house- and residual waste removal 
(WEEE-Richtlinie  2002/96/EG  und  EAG-VO)  ,  it  must  be  disposed  at  the  according 
collection  points.  For  the  protection  of  our  environment  please  inform  yourself  at  your 
communal adminstrative agency about your nearest disposal point. 
 
The  charger  equates  to  the  RoHS-directive  2002/95/EG,  for  the  restriction  of  the  use  of 
certain hazardous substances in electrical and electronic equipment. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Subject to technical modifications. We assume no liability for misprints. 

MEC-Energietechnik GmbH, Energiestraße 3, A-9500 Villach /  www.mec-energietechnik.com 

Input

 

Power supply 

100-240 VAC 

Frequency 

50/60 Hz 

Input voltage 

– 14 VDC 

Power 

max. 18 W 

Output

 

Output voltage 

4 x 1,45 V 

Charge current AA/AAA 

1200/600mA, 900/400mA, 700/250mA  

Discharge curr. AA/AAA 

500/180mA 

Thermic

 

Temperature range 

0°C to +40°C 

Cooling 

Convection cooled 

Dimensions

 

Charger (L x B x H) 

145 x 70 x 45 mm 

Power Supply (L x B x 

H) 

80 x 50 x 80 mm 

Weight 

400g (Charger and Power supply) 

Mains connection 

Power supply w.plug-Typ C (CEE 7/16) 
12V car adapter  

Charging connection 

4 separate charging bays (AA & AAA) 

Certificates

 

Norm 

EN60335-1, EN60335-2-29, IEC60335 

Type 

CE 

Country approval 

GB, EU, AU, NZ 

Summary of Contents for AV4m

Page 1: ... NiMH from 180 to 3300 mAh contempt leads to EXPLOSION RISK ATTENTION Please consider the charging instructions from the battery manufacturer before charging During insertion of the battery please mind the correct polarity Don t use the device near flammable gases solvents or vapours EXPLOSION RISK Use the device only in dry rooms and protect against dust heat 40 C and humidity 80 rel Protect agai...

Page 2: ...top for defective batteries error is displayed Quad display simultaneously display of function and charge status of the inserted batteries Automatic start of the charging process max 1 2 A charge current per battery Automatic switching to trickle charge after end of charging Battery forming automatic forming of damaged batteries Battery capacity measurement display of capacity Ah charging time h a...

Page 3: ...ply with the specifications for a charge start the AV4m starts automatically to charge all detected batteries to their full capacity The charge process is shown in the par ticular display segment via moving bars and the already charged capacity in ampere hours Ah When the charge process has finished the battery symbol in the display is shown statically and full with bars The information about the ...

Page 4: ...ons The validation of the warranty time starts with the de livery date from the manufacturer MEC Energietechnik GmbH is limiting the free guaranteeing to working hours and spare parts only For damages caused by non observance of the operating instructions inappropriate start up or handling as well as reconstructions and modifications of the device the warranty claim expires and MEC Energietechnik ...

Reviews: