Page 12
93808 – October 2014
6092RT
Component Locations
Lower Controls
15
3
7
6
10
2
4
5
9
8
1
Emergency Stop
Circuit Breaker
Preheat
Platform / Base
Lower (Green)
Raise (Green)
Start (Green)
Starter Delay (Red)
Emergency Down
Hour Meter
CONTROL
DESCRIPTION
1
Selector Switch
PLATFORM
Select to operate from the platform control panel.
BASE
Select to operate from the base control panel.
OFF
Select to stop operation from either control panel.
2
LOWER Button
Press and hold to lower the platform. Release to stop lowering.
3
RAISE Button
Press and hold to elevate the platform. Release to stop elevation.
4
Emergency Stop
Switch
Press to stop all machine functions.
Turn
clockwise
to reset.
5
Hour Meter
Indicates total elapsed time of machine operation.
6
Engine Start
Button
After setting the Selector Switch (#1) to BASE, press this button to start the engine.
7
Start Delay
Indicator Light
After 20 seconds of continuous cranking, the engine starter circuit cuts off momentarily to prevent
damage to the starter. This light illuminates when the starter circuit is cut off. Resets after 25 seconds
8
Preheat (Diesel)
Press this button while starting a cold engine
9
Circuit Breaker
Trips when there is excessive electrical load. Push to reset.
10 Emergency Down
Switch
Activate this switch to run the Emergency Down auxiliary hydraulic pump.