![Mec 500E DOUBLES ATA Owner'S Manual Download Page 4](http://html1.mh-extra.com/html/mec/500e-doubles-ata/500e-doubles-ata_owners-manual_1758617004.webp)
Page 4 Rev. 1
UNDERSTANDING THE CONTROL BOX
Rotation Toggle Switch
– Pushing the switch downward will turn the oscillation motor on. Note that
the oscillation motor will randomly start/stop when the machine is in operation. This prevents
shooters from being able to predict the direction of the next target. Pushing the toggle switch upward
allows you to nudge the oscillation motor which pivots the machine from one side to the other
enabling you to check the angle of the clays flight.
Remote Disarm Socket
– The machine is supplied with a remote disarm box assembly and 10ft. of
cable. This unit plugs into the remote disarm socket on the control box, allowing the remote disarm
box assembly to be placed by the opening of the trap house. The user can now disarm the machine
before entering the trap house.
Fire Button
– The fire button allows you to test fire the machine from inside the trap house.
Disarm/Off/Arm
– Pushing the switch downward to the arm state will arm the machine. Pushing the
switch upward will cause the machine to fire (if in armed state) and disarm when the switch is
released. Note
– holding the disarm toggle will continually fire clay targets. Please use caution!
Breakers
– The breaker on the left is for the oscillation motor. The breaker on the right is for the
cocking motor. If the breaker trips, it needs to be pushed back in to reset.
Counter
– Records the number of targets thrown by the machine and is not resettable.
DISARM
OFF
ARM
FIRE
BUTTON
ROTATION
REMOTE
DISARM
SOCKET
COUNTER
OSC.
BREAKER
MAIN
BREAKER