March 2008
"2047ES / 2647ES / 3247ES" Service & Parts Manual - CE Specifications
Page 3-18
CALIBRATION TROUBLESHOOTING; Information messages (continued)
REDO EMPTY:
This message is displayed if the EMPTY phase of load calibration has
previously been completed.
Press ENTER when “NO” is displayed if there is no need to redo the EMPTY
phase.
Press UP or DOWN to display “YES” then press ENTER if it is necessary to
redo the EMPTY phase.
If the previous EMPTY calibration was in error, or if the pressure sensor is
replaced, it will be necessary to redo the EMPTY phase.
REDO LOADED:
This message is displayed if the LOADED phase of load calibration has
previously been completed.
Press ENTER when “NO” is displayed if there is no need to redo the LOADED
phase.
Press UP or DOWN to display “YES” then press ENTER if it is necessary to
redo the LOADED phase.
If the previous LOADED calibration was in error, or if the pressure sensor is
replaced, it will be necessary to redo the LOADED phase.