"2047ES / 2647ES / 3247ES" Service & Parts Manual - CE Specifications
March 2008
Page 3-17
CALIBRATION TROUBLESHOOTING; Information messages (continued)
MEASURING #
This message is displayed when the platform is stopped during either STATIC
phase, when the takes a measurement.
There will be a short delay while the machine is allowed to stabilize after
movement is stopped.
MUST GO DOWN!
This message occurs if the wrong switch is closed when the is waiting for the
platform to be lowered.
MUST GO UP!
This message occurs if the wrong switch is closed when the is waiting for the
platform to be raised.
PLATFORM DOWN?
This message is prompting for confirmation that the platform is fully lowered. If
necessary the DOWN switch can be activated to lower the platform.
Press ENTER to confirm when the platform is fully lowered.
PLATFORM EMPTY?
This message is prompting for confirmation that the platform is completely
empty.
Press ENTER to confirm when the platform is empty.
PLATFORM LOADED?
This message is prompting for confirmation that the platform is loaded to rated
load (this will be 100% for the ).
Press ENTER to confirm when the platform is loaded.
PLEASE LIFT ...
This message is prompting for the platform to be raised.
The UP switch should be closed.
PLEASE LOWER ...
This message is prompting for the platform to be lowered.
The DOWN switch should be closed.
PLEASE WAIT
This message indicates that the is busy; the delay will be short (no more
than 5s).
REDO DYNAMIC:
This message is displayed if the DYNAMIC phase of load calibration has
previously been completed.
Press ENTER when “NO” is displayed if there is no need to redo the DYNAMIC
phase.
Press UP or DOWN to display “YES” then press ENTER if it is necessary to
redo the DYNAMIC phase.
If the previous DYNAMIC calibration was in error, or if the height or pressure
sensor is replaced, it will be necessary to redo the DYNAMIC phase.