CONTINUITY CHECKS
Check Toggle Switch
♦
Disconnect wires and connect one probe of ohm meter to the connection on toggle switch
and the other probe on the other connection.
♦
When toggle is open, there should be no reading, and when closed there should be a low
reading.
Check Selector Switch
♦
Disconnect wires and connect one probe of ohm meter to common and the other to nor-
mally open terminal.
♦
With the switch flipped, there should be a low resistance.
Check Emergency Stop Button
♦
Disconnect wires and connect one probe of ohm meter to connection on button and other
probe on other connection.
♦
There should be no reading with the button pressed and a low resistance with it reset.
Check Limit Switch Operation
♦
Disconnect wires.
♦
With one probe of ohm meter to common and other probe to open contact, move limit
switch arm. Low resistance should be seen.
♦
With one probe of ohm meter to common and other probe to closed contact, low resis-
tance should be seen. Move limit switch arm and no resistance should be seen.
Summary of Contents for 2033ES
Page 28: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page 1 14...
Page 96: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page 5 20...
Page 122: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page A 24...
Page 142: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page B 20...
Page 164: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page C 22...
Page 182: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page D 18...
Page 214: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page E 32...
Page 246: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page E 32...
Page 256: ...October 2008 2033ES 2633ES Service Parts Manual ANSI Specifications Page F 10...