©Measurlogic
Page 2
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: [email protected]
web: www.measurlogic.com
1
PRODUCT OVERVIEW......................................................................................................................................................... 3
1.1
S
UPPLIED
I
TEMS
..................................................................................................................................................................... 3
1.2
D
OCUMENT
C
ONVENTIONS
...................................................................................................................................................... 4
1.3
P
RODUCT
S
PECIFICATION
......................................................................................................................................................... 4
1.3.1
Current Inputs ............................................................................................................................................................ 4
1.3.2
Service Type ............................................................................................................................................................... 4
1.4
DTS 310 L
AYOUT
................................................................................................................................................................... 5
2
INSTALLATION ................................................................................................................................................................... 6
2.1
E
NVIRONMENT
....................................................................................................................................................................... 6
2.2
S
AFETY
G
UIDELINES
................................................................................................................................................................ 6
2.3
P
RODUCT
D
IMENSIONS
............................................................................................................................................................ 7
2.4
M
OUNTING
R
EQUIREMENTS AND
G
UIDELINES
............................................................................................................................. 7
3
CONNECTING TO THE DTS 310 ........................................................................................................................................... 8
3.1
W
IRING
V
OLTAGE AND
C
URRENT
I
NPUTS
.................................................................................................................................... 8
3.1.1
Wiring Examples ........................................................................................................................................................ 8
3.2
C
ONNECTING
M
ULTIPLE
L
OADS
................................................................................................................................................. 9
3.3
DC A
UXILIARY
P
OWER
........................................................................................................................................................... 10
4
MAINTENANCE AND SERVICE........................................................................................................................................... 11
5
DTS 310 COMMUNICATIONS INTERFACE.......................................................................................................................... 11
5.1
M
ODBUS AND
BAC
NET
RS-485 2-W
IRE
C
OMMUNICATIONS
....................................................................................................... 11
5.2
L
ON
W
ORKS
TP/FT – 10 C
OMMUNICATIONS
............................................................................................................................. 12
5.2.1
Wiring Requirements ............................................................................................................................................... 12
5.2.2
Adding the DTS 310 to an existing LonWorks Network via Service Pin.................................................................... 12
5.2.3
Adding the DTS 310 to an existing LonWorks Network via Neuron ID .................................................................... 12
5.3
E
THERNET
C
OMMUNICATIONS
................................................................................................................................................ 13
5.4
K
W
H
P
ULSE
O
UTPUT
(M
ODEL
D
EPENDENT
).............................................................................................................................. 13
5.5
C
ONFIGURING
DIP S
WITCHES
– C
OMMUNICATION AND
P
ULSE
O
UTPUT
S
ETTINGS
............................................................................ 13
5.5.1
Configuring DIP Switches – Modbus RTU................................................................................................................. 14
5.5.2
Configuring DIP Switches – BACnet MS/TP.............................................................................................................. 14
5.5.3
Configuring DIP Switches – Pulse Output................................................................................................................. 15
6
LED DEFINITIONS ............................................................................................................................................................. 16
6.1
S
TATUS
LED........................................................................................................................................................................ 16
6.2
R
EMOTE
LED....................................................................................................................................................................... 16
6.3
P
ULSE
LED.......................................................................................................................................................................... 17
7
INSTALLATION OF DTS CONFIG AND MONITORING SOFTWARE ....................................................................................... 17
8
MAINTENANCE AND SERVICE........................................................................................................................................... 17
8.1
C
LEANING
I
NSTRUCTIONS
....................................................................................................................................................... 17