a) Red clip to POSITIVE (+) terminal.
b) Black Clip to NEGATIVE (-) terminal.
3)
Connect cable 40043-240 to the connector on the side of the
meter labeled POWER.
CAUTION: Ensure proper pin alignment. Do not attempt to force
connector into place.
4)
Operate the system as in Battery Operation steps 1-8.
Note: The engine of the vehicle to which the system is connected
should be running to ensure constant 12 Volt power availability.
CALIBRATION PROCEDURE
The Bantam has been calibrated at the factory and is ready for use.
Recalibration of the system may be accomplished should the Bantam
weight readings differ significantly from those obtained at a certified
scale.
Note: The Battery should be fully charged for this operation.
1)
Turn the ON/OFF switch to on, verify that all display segments
and lamps are on during the segment check, then off again before
the program number is displayed (P-XX).
2)
With no load on the weigh pads wait for a stable display reading
and push the zero switch to zero the display.
3)
Push the Cal Switch. The Cal number (found on the serial number
tag under the meter lid) should appear on the display. If the
displayed Cal number agrees with the Cal number on the serial
number tag, skip to step 5.
4)
Adjust the SPAN screw with the Cal switch pushed until the
proper calibration number appears.
5)
Release the Cal Switch and verify that the display returns to zero.
If not, repeat steps 2-4.
Note: Perform the following steps for each weigh pad.
6)
Connect an unloaded weigh pad to the meter.
7)
Push the ZERO switch to zero the display.
!
CAUTION
CAUTION