Chapter 5
94
Testing Single-Value Analog Input
To verify that the board can read a single analog input value, do the following:
1.
Connect a voltage source, such as a function generator, to analog input channel 0
(differential mode) on the DT3010 Series board. Refer to
for an example of how to
connect a differential analog input.
2.
In the Quick DataAcq application, choose
Single Analog Input
from the
Acquisition
menu.
3.
Select the appropriate DT3010 Series board from the Board list box.
4.
In the Channel list box, select analog input channel 0.
5.
In the Range list box, select the range for the channel.
The default is ±10 V.
6.
Select
Differential
.
7.
Click
Get
to acquire a single value from analog input channel 0.
The application displays the value on the screen in both text and graphical form.