SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
Note.10
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
500ms, 100ms/115VAC, 230VAC
47 ~ 63Hz
0.29A / 115VAC 0.15A / 230VAC 0.13A/277VAC
<0.75mA / 277VAC
20 ~ 95% RH non-condensing
-40 ~ +80
℃
±
0.03%/
℃
(0 ~ 60
℃
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
105
*
63
*
30mm (L*W*H)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
88%
TOTAL HARMONIC DISTORTION
RATED CURRENT (Default)
RATED POWER
CURRENT ADJ. RANGE
SETUP, RISE TIME
Note.3
OPEN CIRCUIT VOLTAGE (max.)
CONSTANT CURRENT REGION
Note.2
SAFETY STANDARDS
Note.8
COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VAC
μ
;
Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
MAX. CASE TEMP.
Tcase=+85
℃
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 305VAC 127 ~ 431VDC
℃
℃
℃
℃
※
:
,
https
://
www
.
meanwell
.
com
/
serviceDisclaimer
.
aspx
110-150% Over Power Protection, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
PF
≧
0.97/115VAC, PF
≧
0.95/230VAC, PF
≧
0.92/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 10%(@load
≧
50%/115VC,230VAC; @load
≧
75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
No load power consumption <0.5W for A,<0.75W for I series
NO LOAD / STANDBY
POWER CONSUMPTION
Standby power consumption <0.5W for AB-Type(Dimming OFF)
Tcase=-40 ~ +85
℃
(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC AS/NZS IEC BS EN/EN61347-1, AS/NZS BS EN/EN61347-2-13 independent, BS EN/EN62384;
IP67; GB19510.1,GB19510.14,
,
,
EAC TP TC 004
,
KC61347-1
,
KC61347-2-13
IS15885(Part2/Sec13)( for XLG-25I
J61347-1(H29), J61347-2-13(H29)
type only); NOM
-
058
-
SCFI
-
2017
approved
3931.6 K hrs min. Telcordia SR-332 (Bellcore) 399.9Khrs min. MIL-HDBK-217F (25
)
℃
XLG-25 -
0.25 ~ 1.05A
22 ~54V
25W
700mA
90VAC ~ 305VAC
File Name:XLG-25-SPEC 2022-08-08
57V
5.0% max. @rated current
CURRENT RIPPLE
OVER TEMPERATURE
Hiccup mode, recovers automatically after fault condition is removed
INPUT OVER VOLTAGE
Note.8
320 ~ 370VAC
(Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours
max
@ tc 75
℃
SHORT CIRCUIT
OVER POWER
0.41Kg;24pcs/ 10.5Kg/0.68CUFT for A-type 0.42Kg;24pcs/ 11Kg/0.68CUFT for AB-type
25W Constant Power Mode LED Driver
XLG-25
series
OVER CURRENT
Constant current limiting, recovers automatically after fault condition is removed
EMC EMISSION
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
BS EN/EN61000-3-3
Test Level/Note
-----
-----
Class C @load≥50%
-----
EMC IMMUNITY
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Standard
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-5
BS EN/EN61000-4-6
BS EN/EN61000-4-8
BS EN/EN61000-4-11
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
BS EN/EN61547
BS EN/EN55015(CISPR15) ,GB/T17743
BS EN/EN55015(CISPR15) ,GB/T17743
BS EN/EN61000-3-2 ,GB/T17625.1
4KV/Line-Line 6KV/Line-Earth