SPECIFICATION
RSP-2400-12
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
OUTPUT VOLTAGE
PROGRAMMABLE(PV)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD (OLP)
OVER VOLTAGE
AC CURRENT (Typ.)
12V
166.7A
0 ~ 166.7A
2000.4W
150mVp-p
10.8 ~ 13.2V
±
1.0%
±
0.5%
±
0.5%
1000ms, 80ms at full load
12ms at full load
180 ~ 264VAC 254 ~ 370VDC
47 ~ 63Hz
88%
15.5A/180VAC 12A/230VAC
60A/230VAC
<2.0mA / 240VAC
100 ~ 112% rated output power
13.8 ~ 16.8V
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover
28.8 ~ 33.6V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +70
(Refer to "Derating Curve")
℃
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
℃
±
℃
℃
0.05%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
234.1K hrs min.
Telcordia SR-332 (Bellcore) ; 83.9K hrs min. MIL-HDBK-217F (25
)
℃
278*177.8*63.5mm (L*W*H)
3.3Kg; 4pcs/14.2Kg/1.81CUFT
90.5%
91.5%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
±
1.0%
±
1.0%
150mVp-p
22 ~ 28V
200mVp-p
43 ~ 56V
24V
100A
0 ~ 100A
2400W
48V
50A
0 ~ 50A
2400W
RSP-2400-24
RSP-2400-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4.
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a
mm*
mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.
720
360
For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
POWER FACTOR (Typ.)
0.95/230VAC at full load
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
℃
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 4)
PROTECTION
2400W Power Supply with Single Output
R S P - 2 4 0 0
s e r i e s
ALARM SIGNAL OUTPUT
REMOTE ON-OFF CONTROL
AUXILIARY POWER
Please refer to the Function Manual
Power OK signal. Please refer to the Function Manual
[email protected](Only for Remote ON-OFF control)
Please refer to the Function Manual.
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual.
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024 , EN61204-3, EN61000-6-2
Standard
Standard
EN55022 (CISPR22) / EN55011 (CISPR11)
EN55022 (CISPR22) / EN55011 (CISPR11)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class A
-----
-----
EMC IMMUNITY
EMC EMISSION
File Name:RSP-2400-SPEC 2016-07-26
4.8 ~ 28V
9.6 ~ 56V
2.4 ~ 13.2V
CURRENT SHARING
Up to 7200W or (2+1) units. Please refer to the Function Manual.
Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line