Main Specification

VOLTAGE ADJ. RANGE

105 ~ 115% rated output power

MODEL

DC VOLTAGE
RATED CURRENT

OUTPUT

LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE

Note.4

FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)

Note.10

INPUT

INRUSH CURRENT (Typ.)
LEAKAGE CURRENT

OVER TEMPERATURE

WORKING TEMP.

WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION

DIMENSION

OTHERS

NOTE

OVERLOAD

OVER VOLTAGE

AC CURRENT (Typ.)

1500ms, 60ms/230VAC at full load

90 ~ 264VAC          127 ~ 370VDC

Cold start 80A/230VAC

2mA / 240VAC

-30 ~ +70

Baseplate temperature (Refer to “Derating Curve")

20 ~ 90% RH non-condensing

-40 ~ +85

, 10 ~ 95% RH non-condensing

±

℃)

0.03%/

(0 ~ 50

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

183.4K hrs min.

Telcordia SR-332 (Bellcore) ; 56.26K hrs min.      MIL-HDBK-217F (25

)

PF

0.95/230VAC at full load

16ms/230VAC at 75% load          10ms/230VAC at full load

RIPPLE & NOISE (max.)

Note.2

VOLTAGE TOLERANCE

Note.3

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance :

line regulation and load regulation.

includes set up tolerance,

4. Derating may be needed under low input voltages. Please check the 

 for more details.

derating curve

5. Without water or fan cooling to provide adequate heat dissipation, OTP might be triggered if trimming output voltage by PV signal toward upper or bottom 

    limits of nominal voltage. Under such condition, enhanced cooling on PSU is highly recommended.

6. PV/PC function when users are not operating on PMBus. SVR functions when users are neither operation on PMBus nor using PV/PC.

7. Need additional EMI filter to meet regulations of EMC conducted and radiated emission. Characteristics of EMI filter please refer to the table, Minimum 

    Insertion Loss.

8. 

 

The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on 

  a 

mm*

mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.

600

900

 For guidance on how to 

    perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).

10. The efficiency is measured at 75% load.

ENVIRONMENT

PROTECTION

380*141.4*60mm (L*W*H)

Protection type :Shut down O/P voltage,re-power on to recover

Protection type :Shut down O/P voltage, recovers automatically after temperature goes down

20A/230VAC

RATED POWER

(convection)

4.5Kg;4pcs/19Kg/2.51CUFT

47 ~ 63Hz

Protection type : Constant current limiting, shut down O/P voltage 5 sec. after O/P voltage is down low, re-power on to recover

FUNCTION

REMOTE ON/OFF CONTROL
AUXILIARY POWER
DC-OK SIGNAL

Power ON :  Short circuit          Power OFF : Open circuit

[email protected] tolerance 10%, ripple 150mVp-p

±

The TTL signal out, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V.  Please refer to the Function Manual.

SAFETY STANDARDS

SAFETY &
EMC

(Note.7,8)

WITHSTAND VOLTAGE
ISOLATION RESISTANCE

I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25

/ 70%RH

UL62368-1,TUV EN62368-1,

approved ; design refers to EN61558-1, EN60335-1

EAC TP TC 004

MTBF

PACKING

Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.

OUTPUT VOLTAGE
PROGRAMMABLE(PV)

Note.5,6

OUTPUT CURRENT
PROGRAMMABLE(PC)

Note.6

By built-in potentiometer, SVR

300mVp-p

480mVp-p

±

0.5%

±

0.5%

±

0.5%

±

0.5%

±

1.0%

±

1.0%

95%

96%

30 ~ 36V

60 ~ 72V

PHP-3500-24

PHP-3500-48

3480W

3504W

24V

48V

145A

73A

24~28.8V

48~57.6V

EMC IMMUNITY

EMC EMISSION

Parameter

Parameter

ESD

Radiated

EFT / Burst

Surge

Conducted

Magnetic Field

Voltage Dips and Interruptions

Conducted

Radiated

Harmonic Current

Voltage Flicker

Standard

Standard

EN55032 (CISPR32) / EN55011 (CISPR11)

EN55032 (CISPR32) / EN55011 (CISPR11)

EN61000-3-12

EN61000-3-3

EN61000-4-2

EN61000-4-3

EN61000-4-4

EN61000-6-2

EN61000-4-6

EN61000-4-8

EN61000-4-11

Test Level / Note

Test Level / Note

Level 3, 8KV air ; Level 2, 4KV contact

Level 3

Level 3

2KV/Line-Line 4KV/Line-Earth

Level 3

Level 4

>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods

Class B

Class A

-----

-----

OVER VOLTAGE CATEGORY

; According to EN61558; altitude up to 5000 meters.

Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage. Please refer to the Function Manual.

Summary of Contents for PHP-3500

Page 1: ...PHP 3500 User s Manual...

Page 2: ...Input Voltage Range 3 2 Inrush Current Limiting 4 2 Derating 4 1 Installation Method 3 3 Rated Power 3 4 Power Factor Correction PFC 3 5 Output Voltage Current Adjustment 3 6 Short Circuit and Over Cu...

Page 3: ...al AC input Full range Built in active PFC function PF 0 95 Protection Short circuit Overload Over voltage Over temperature Built in remote ON OFF control Output voltage programming Output current pro...

Page 4: ...uidance on how to perform these EMC tests please refer to EMI testing of component power supplies as available on http www meanwell com 9 The ambient temperature derating of 3 5 1000m with fanless mod...

Page 5: ...erload protection Fan fail Red Flashing The LED will flash with red light when internal temperature reaches under this condition the unit still operates normally without entering 85 OT In the meantime...

Page 6: ...terface Note 2 For CANBus model Data line used in CANBus interface Note 2 SDA CANH 17 18 The signal return is isolated from the output terminals V V GND AUX S Connection for constant current level pro...

Page 7: ...Figure 3 1 Connection of external DC voltage source PV 5 6 1 0 5V V Figure 3 2 Note The PHP 3500 will trigger OLP to shut down itself if the output stays at constant current level condition for more t...

Page 8: ...e 3 3 for the control method Please be aware that ON OFF and 12V AUX on CN47 should be linked together to allow the unit operate normally If they are kept open there will be no output voltage Maximum...

Page 9: ...gned When DIP switch in the ON position means logic 0 when it is in the OFF position meaning logic 1 for example position 3 in OFF the corresponding bit A2 is set to logic 1 Please refer to Table 3 1...

Page 10: ...ommands 01h 22h and 46h are saved into EEPROM and take effect after the digital 3 1 3 5 PMBus Command List The command list of the PHP 3500 is shown in Table3 2 It is compliant with the standard proto...

Page 11: ...1 The PFC activate 1 Active dummy load activate 1 The unit in an initial state Note Unsupported settings display with 0 0b10 Power on with the last setting 0b11 Not used Note Unsupported settings dis...

Page 12: ...rent Model Model 24V 24V 12 28 8V 48V 48V 24 57 6V Table 3 6 Table 3 5 Note 2 When using PMBus to adjust output voltage VOUT_COMMAND only can be used to display the rated voltage of the unit and 4 Dat...

Page 13: ...nteger IRECT format data may be used with any command that sends or reads a arametric value If a PMBus device uses DIRECT form data this shall be clearly described in the product literature The host s...

Page 14: ...AC input voltage the unit will derate its output current automatically to protect itself shown as Figure 4 2 12 LOAD INPUT VOLTAGE VAC 60Hz 90 100 115 180 264 100 50 12AWG UL1015 12AWG UL1015 50mm 22...

Page 15: ...o avoid condensation please follow below Flatness between mating parts plays a critical role in thermal contact conductance Please make sure cooling capacity of the chiller is greater than 175W so as...

Page 16: ...Ordering No HS 656 4 5 Warranty A five year global warranty is provided under normal operation Please do not change any component or modify the unit by yourself or MEANWELL may reserve the right not...