SPECIFICATIONS

Main Unit
Indoor Temperature

Operating range: 23.0°F to 122.0°F (-5°C to +50°C)
Temperature resolution: 0.2°F (0.1°C)
User-selectable (°F or °C) temperature display

Humidity (Indoor)

Operating Range: 30% to 80%
Resolution: 1%
Accuracy: 7% 
Sampling Interval: 10 seconds

Weather Forecast:

 in seven large icons: sunny, slightly cloudy, cloudy, rainy, heavy rainy, 

snowy and heavy snowy.
Maximum number of remote sensors: 3 (one included)
Readings update interval: every 45 seconds
Low battery indicator

Clock

Precise atomic time
4 US Time Zones
12/24 hour time format
Crescendo 2 minutes alarm with 8 minutes snooze

Barometric Pressure 

Measuring Range: 14.75 inHg to 32.44 inHg (500 Hpa to 1100Hpa); 
(374.5 mmHg to 823.8 mmHg)
Resolution: 0.003 inHg (0.1 Hpa, 0.08 mmHg)
Accuracy: 0.015 inHg (5 Hpa; 0.38 mmHg)
Sampling interval: 20 minutes
Altitude Compensation Range: -657 ft to 16404 ft (-200m to +5000 m)

Remote Sensor
Remote Temperature

Operating range with lithium batteries:
-40°F to 122°F (-40°C to 50°C)
Temperature resolution: 0.1°C/0.2°F

Humidity (Outdoor)

Operating Range: 30% to 80%
Resolution: 1%
Accuracy: 7% 
Sampling Interval: 10 seconds
Transmitting Interval: around 47 seconds
RF Transmission Frequency: 433 MHz
RF range: Maximum 164 feet (50 meters) 
Temperature transmission cycle: approximately 45 seconds 
Low battery indicator
Wall-mount or Table stand

Power

Main unit: 2 CR2032 lithium cell batteries (included)
Remote Sensor: 2 AAA size 1.5V batteries (not included)

Dimensions

Main unit: 7.01(L) x 4.72(H) x 0.37(D) inches/ 178(L) x 120(H) x 9.5(D) mm
Remote sensor: 1.48(L) x 4.33(H) x 0.91(D) inches / 37.5(L) x 110(H) x 23(D) mm

16

Summary of Contents for TE636W

Page 1: ...TE636W Slim Weather Forecaster with Indoor Outdoor Temperature and Humidity USER MANUAL...

Page 2: ...us for its innovative high performance telescopes at affordable prices Meade Instruments now brings that same passion for innovation and high performance to its own line of precision feature rich weat...

Page 3: ...nsor before the main unit Insert batteries before first use matching the polarity in the battery compartment Press RESET after each battery change with a paper clip or similar tool During initial set...

Page 4: ...lt in reduced the transmission range For optimum performance in cold weather conditions we recommend using lithium batteries NOTE Install the batteries before mounting the remote sensor Remove the scr...

Page 5: ...art transmitting a temperature and humidity data to the main unit MAIN UNIT FEATURES TIME Precise time and date set via signals from the US Atomic clock 12 or 24 hour time format Manual adjustment of...

Page 6: ...FRONT REAR A J K L B C G H D I F E 6...

Page 7: ...and hold for 2 seconds to set altitude and sea level When time mode has been selected press once to toggle between time with seconds display or time with weekday display Press and hold for 2 seconds s...

Page 8: ...IMPORTANT All of the display functions will be locked allowing setting of your local altitude and pressure parameters by pressing the UP or DOWN and SET buttons The locked display will show the press...

Page 9: ...emotes stabilize pressure readings and settle with default settings SELECT PRESSURE UNITS OF MEASURE Press UP or DOWN as needed until the pressure icon PRESSURE to the left of the barometric pressure...

Page 10: ...als If no buttons are pressed for 5 seconds the unit will automatically return to the default Pressure and Weather Forecast Mode VIEWING PRESSURE TEMPERATURE AND HUMIDITY CHARTS The bar chart in Press...

Page 11: ...viewing NOTE the channel auto scan feature can be active only if there are more than one remote sensors operating and are set to different channels PROGRAMMING TEMPERATURE IN CELSIUS OR FAHRENHEIT Pr...

Page 12: ...quency The main unit can receive this WWVB signal through the internal antenna from up to 2 000 miles away Due to the nature of the Earth s ionosphere reception can be limited during the daylight hour...

Page 13: ...ZONE TIME ZONE Press MODE button once to select hour and minutes with the day of the week display Select the Time Zone by pressing and holding UP button for 3 seconds Keep holding UP button until the...

Page 14: ...nfirm and the weekday alarm time will be set Set Single S day alarm if desired in the same manner SETTING THE ICE WARNING ALARM PRE AL If Weekday W or Single day S alarm is set the Ice Warning Alarm P...

Page 15: ...atisfactory service if handled carefully Here are a few precautions Do not immerse the units in water Do not clean the units with abrasive or corrosive materials They may scratch the plastic parts and...

Page 16: ...to 823 8 mmHg Resolution 0 003 inHg 0 1 Hpa 0 08 mmHg Accuracy 0 015 inHg 5 Hpa 0 38 mmHg Sampling interval 20 minutes Altitude Compensation Range 657 ft to 16404 ft 200m to 5000 m Remote Sensor Remot...

Page 17: ...o an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORMITY We Name Meade Instruments Co...

Page 18: ...nt detailing the nature of the claimed defect as well as the owner s name address phone number and a copy of the original sales invoice This warranty is not valid in cases where the product has been a...

Page 19: ...Meade Instruments Corp 27 Hubble Irvine CA 92618 U S A 2011 Meade Instruments Corp All Rights Reserved All user manual contents and information are subject to change...

Reviews: