DEHUMIDIFIER SETUP AND USE                                                                                               

 

Place the dehumidifier in an upright position on a stable, flat surface. 

 

Please ensure the unit is a safe distance away from a wall or furniture. 

 

The unit will bleep three times when the power cord is inserted into the socket. 

 

Run the hose to a drain point no more than 3.5 metres above the height of the drain on the dehumidifier. 

 

Press the Power button

.    The dehumidifier will start up in Continuous dehumidification mode. 

 

Select the Mode that you want to use the dehumidifier in using the 

  button. 

 

To turn off press the Power 

  button again. 

Pump Operation 

 

When the internal tank is full the dehumidifier will automatically turn the pump on for two minutes.    When this happens 

the Pump icon on the LCD will flash.    Before you turn the dehumidifier off you can press the Pump button to manually 

drain the excess water from the internal tank.    We recommend doing this before moving the dehumidifier to prevent 

spillage.    Water can also be drained by removing the drainage stopper from the base of the dehumidifier. 

Timer Operation 

 

To reset the Run Timer press and hold the 

  and 

  button for 8 seconds. 

High and Low temperature protection 

 

If the air inlet temperature and relative humidity sensor reads 

≤0°C or ≥40°C then the dehumidifier will stop running and 

the buzzer will sound three long notes and two short notes.    In this situation the buttons will cease to respond when 

pressed.    When the temperature returns to normal please unplug the dehumidifier and then plug it back in again so 

that it will start to operate normally again. 

 

Compressor Protection 

 

 

In common with other dehumidifiers the Meaco 70Lm will 

not start up it’s compressor within three minutes of start up.

 

To operate safely 

 

 

Do not insert small objects into the unit or this will damage it and cause a hazard. 

 

Do not remove the tank when the dehumidifier is running or water may leak. 

 

Minimum operating condition 5°C at 50%rh relative humidity. 

 

 

 

       

ATTENTION ! 

 

Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or 
allow it to come into contact with sharp edges.

 

 

Failing to follow the instructions may lead to the guarantee becoming void.

 

 

 

 

Summary of Contents for 70Lm

Page 1: ...struction Manual Meaco 70Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really appreciate it Exten...

Page 2: ...2 PRODUCT DESCRIPTION Handle Filter Air Intake Slats Front Casing Wheel Control Panel Air Outlet Hose Support Drainage Connect Drainage Stopper Power Cord Base Pad...

Page 3: ...ace anything on top of the unit and do not cover with any kind of material while in use 9 This product is intended for indoor us only 10 To protect against electrical shocks do not immerse unit plug o...

Page 4: ...connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The...

Page 5: ...the button to cycle through the different set points 40 rh 50 rh 60 rh 70 rh 80 rh Continuous Press to start the pump manually Fan Room Temperature Run Timer Defrosting Target relative humidity Room r...

Page 6: ...rainage stopper from the base of the dehumidifier Timer Operation To reset the Run Timer press and hold the and button for 8 seconds High and Low temperature protection If the air inlet temperature an...

Page 7: ...ollow these steps Remove the filter Clean the filter with a vacuum cleaner and if necessary with water Make sure that the filter is dry before you put it back into the dehumidifier STORAGE If the mach...

Page 8: ...second dehumidifier There are too many sources of moisture putting moisture into the air Either buy a second dehumidifier reduce the amount of moisture being put into the space or accept a longer dry...

Page 9: ...ult is found to be the result of a buildup of dirt and insufficient cleaning of the filter All claims for compensation including consequential damage will not be entertained To prevent unnecessary exp...

Page 10: ...R410a 440g Dimensions w x d x h 631 x 440 x 460mm Net weight 43 5kgs This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible h...

Page 11: ...for buying the dehumidifier we have the following discount code which can be used by yourself friends or family to receive 10 00 off your next purchase at www meaco com when you or they spend 50 00 o...