SAFTEY INFORMATION 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

This dehumidifier must not be used in rooms under the following conditions:  
- Potentially explosive atmosphere 
- Aggressive atmospheres 
- Featuring a high concentration of solvents  
- An extremely high ratio of dust

 

 

 

Keep Children Away: 

Do not allow children to play with or around this unit, which could result in injury. 

Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by 
person (including children) with reduced physical, sensory or mental capabilities, or lack of experience 
and  knowledge,  unless  they  have  been  given  supervision  or  instruction  concerning  use  of  the 
appliances by a person responsible for their safety.

 

Keep Unit Grounded:

 Always operate the unit with a grounding plug and a grounded electrical outlet. 

A grounding plug is an essential safety feature that helps reduce the risk of shock or fire. 

 

Protect  Power Cord from Damage: 

Never operate  a unit with a  damaged power cord, as this may 

lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of 
the same type and amperage rating. 

 

Extension Cords: 

Extension cords must be grounded and able to deliver the appropriate voltages to 

the unit. 

 

External Timers: 

Never operate the dehumidifier with an external timer. Doing so could damage the 

internal components and will decrease the lifespan of the product. Using the unit with an external timer 
will invalidate the warranty. 

 

Handle with  Care

:  Do  not  drop,  throw  or  crash  the  dehumidifier.  Rough  treatment can  damage  the 

components or wiring and create a hazardous condition. 

 

Run on Stable Surface: 

Always operate the unit on a stable, level surface, for example the floor or a 

strong counter, so that the dehumidifier cannot fall and cause injury. 

 

Keep Out of Water: 

Never operate the unit in pooled or standing water, as this may create a risk of 

injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become 
wet, thoroughly dry them before using the unit. If in doubt do  not use the dehumidifier and consult a 
qualified electrician or a Meaco approved engineer. 

 

Do Not Let Water Drip onto the Dehumidifier: 

Do not allow water to drip onto the dehumidifier at any 

time

.

 

Keep Air Intakes Clear: 

Do not clog or block the air intakes by placing the dehumidifier too close to 

curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result 
in a fire or electrical hazard. 

 

Keep the Filter Clean: 

There is a filter on the air inlet to stop dust from getting inside the dehumidifier. 

If you allow the dust and dirt to build up on the filter, pressure on the fan motor will be increased and 
you will reduce the amount of water extracted from the air. Not cleaning the filter reduces the lifespan 
of the dehumidifier,  increases energy consumption  and decreases  water  extraction.  Please  examine 
and clean the filter a minimum of every week.

 

Keep Electrical Components Dry: 

Never allow water inside the dehumidifier’s electrical components. 

If  these  areas  become  wet  for  any  reason,  thoroughly  dry  them  before  using  the  dehumidifier.  If  in 
doubt, do not use the dehumidifier and consult a qualified electrician or a Meaco approved engineer. 

 

The operator must make the operating instruction available for the user and make sure that the user 
does understand the manual.   

 

Summary of Contents for 50Lm-v2

Page 1: ...50Lm v2 Instruction Manual Meaco 50Lm Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we really apprecia...

Page 2: ...azardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the dehumidifier cannot fall and cause injury Keep Out of W...

Page 3: ...om must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by an operating electric heaters operating gas a...

Page 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Page 5: ...ry The fan takes the humid air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the...

Page 6: ...RODUCT IDENTIFICATION Front of the dehumidifier Back of the dehumidifier Pushing handle Control panel Air inlet Lift handle Water tank cover Big wheel Air outlet Power cord hook Power cord Radiator gr...

Page 7: ...INSTALLATION Before use 1 Remove the dehumidifier from the packaging and take down the hand screw 2 Rotate the pushing handle aim it at the hole site then tighten the hand screws 3 Installation comple...

Page 8: ...s drainage 1 Open the front panel remove the water tank and empty its contents 2 Remove the plug and attach the drainage pipe to the connector Direct the pipe to its desired drainage outlet before tur...

Page 9: ...buttons to set the number of hours in which you want the dehumidifier to turn off Once the count down has finished the fan and compressor will turn off Press the timer button for three seconds to see...

Page 10: ...multaneously opens the solenoid value Hot gas is guided into the evaporator until the latter is completely free of ice Subsequently the dehumidifier will operate again in its normal mode when the temp...

Page 11: ...um of every two weeks not doing so could invalidate the units warranty Please use the following steps Pull the louvre on the front panel to gain access to the filter Remove the filter from the dehumid...

Page 12: ...h a relative humidity from 20 rh to 90 rh It is suitable for applications residential buildings offices museums archives garages and storage rooms Temperature Range 5 C 38 C Relative Humidity Range 20...

Page 13: ...dehumidifier only works between 5 C and 38 C LO The room humidity is below 20 rh There humidity level is too low there is no moisture to collect HI The room humidity is very high and above 95 rh Set...

Page 14: ...damage caused by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not...

Page 15: ...harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return...

Reviews: