background image

 

17

 

 

SPECIFICATIONS 

--------------------------------------------------------------------------------------------------------------------- ------------------

 

 

 

 

Meaco 12L Low Energy 

Dehumidifier 

Meaco 20L Low Energy 

Dehumidifier 

 

Extraction 

Rate  

 

 

at 30°C and 

80%rh 

 

12 litres per day 

20.38 litres per day 

 

at 20°C and 

60%rh 

 

4.77 litres per day 

8.48 litres per day 

 

Variable humidistat 

 

Yes between 30%rh and 

80%rh  

Yes between 30%rh and 

80%rh 

 

Louvre 

 

Yes (manual) 

Yes (automatic) 

 

Air flow (nominal) 

 

90m³/hour 

160m³/hour 

 

Auto-restart 

 

Yes 

Yes 

 

Filter 

 

Yes (and an optional HEPA 

filter) 

Yes (and an optional HEPA 

filter) 

 

Noise level at one metre 

 

Maximum 41dB(A) 

Maximum 46dB(A) 

 

Power supply 

 

230V, 50Hz 

230V, 50Hz 

 

Power consumption at 20°C 

and 60%rh 

 

157W 

219W  

 

Fan speeds 

 

One 

Two

 

 

Operating temperatures 

 

+5 °C / +35°C 

+5 °C / +35°C 

 

Refrigerant 

 

R290 

R290 

 

Tank 

 

2.5 litres 

6 litres 

 

Dimensions (HWD) 

 

475 x 325 x 248mm 

595 x 385 x 290mm 

 

Weight 

 

9.8Kgs 

13.6Kgs 

Summary of Contents for 12L Low energy Dehumidifier

Page 1: ...Air Purifier Instruction Manual Meaco 12L and 20L Low Energy Dehumidifier Air Purifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you f...

Page 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Page 3: ...r stored in a non ventilated area then the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by...

Page 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Page 5: ...re the air is cooled below dew point so that the water vapour of the air forms a condensate on the coils which flows into the internal container ready to be poured away The cooled and dried air is hea...

Page 6: ...mentally friendly For this reason we have stopped including continuous drainage hoses in our dehumidifiers to reduce the amount of plastic waste created as most of our customers do not use them If you...

Page 7: ...k and insert it into the spout which drips into the water tank Snip the circular disc on the back of the unit to the bottom right of the filter and push the 12mm hose through the hole securing it to t...

Page 8: ...o clean the inside of the 20L Low Energy water tank the lid needs to be removed via the handle Turn the handle to align the handle grooves with the circular holes on the water tank Gently squeeze both...

Page 9: ...60 55 50 45 40 35 30 CO AP OFF TIMER BUTTON The OFF Timer acts as a countdown timer This can be used if you want the dehumidifier to run for a set number of hours and then switch off Press the OFF Ti...

Page 10: ...n the environment For more information of AP or CO mode see page 13 Once the target humidity level has been reached is more than 3 below the dehumidifier will go to sleep for half an hour and the read...

Page 11: ...AP OFF TIMER BUTTON The OFF Timer acts as a countdown timer This can be used if you want the dehumidifier to run for a set number of hours and then switch off Press the OFF Timer button and then use...

Page 12: ...d its target humidity level This light will be solid it will not flash If the light is flashing it is in defrost mode DEFROST MODE This dehumidifier is equipped with an automatic defrosting system Whe...

Page 13: ...ir Purification mode To achieve this mode keep pressing the DOWN arrow until AP appears on the display In this mode the dehumidifier will not collect any water but all the air that goes through the de...

Page 14: ...e landing or hallway If you have more of a problem in one area of your house flat place the dehumidifier closer to that area Leave all the interior doors open and keep the windows closed Moisture in t...

Page 15: ...y two weeks not doing so could invalidate the units warranty Please use the following steps Remove the filter it can be found inside the fitted filter frame Clean both sides of the filter with the end...

Page 16: ...ollowing steps 1 Remove the plug from the socket and empty the water tank Allow the water tank and the dehumidifier to dry completely this can take a couple of days 2 Clean the filter and store the de...

Page 17: ...and 80 rh Louvre Yes manual Yes automatic Air flow nominal 90m hour 160m hour Auto restart Yes Yes Filter Yes and an optional HEPA filter Yes and an optional HEPA filter Noise level at one metre Maxim...

Page 18: ...ondition the dehumidifier becomes inefficient and little water will be collected The air filter is dirty and blocked The air filter must be cleaned If the air filter is beyond cleaning it must be repl...

Page 19: ...owing out warm air The dried air is passed over heating coils before it is blown into the room as part of the dehumidification process This is normal a dehumidifier is not an air cooler Dehumidifier i...

Page 20: ...f the unit once the filter has been removed The humidity reading jumps up to a high figure The dehumidifier is reading its internal humidity This is not a fault it is part of the dehumidifiers process...

Page 21: ...escribed in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation...

Page 22: ...m to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and...

Reviews: