background image

 

15

 

 

MAINTENANCE 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

Always turn off the power and disconnect the main cable before performing maintenance procedures.  

INSPECT ELECTRICAL SYSTEM

 

 

Inspect the electrical cord for damage at regular intervals.  

 

CLEANING THE EXTERIOR 

 

 

Clean the exterior with a soft, dry cloth. If the  device  is extremely dirty, use  a mild cleaning 
agent or wipe the dehumidifier with a slightly damp cloth. Never spray the device with water.

 

 

CLEANING THE FILTER 

The filter is a life-long filter which should not need to be replaced (other than for wear and tear reasons). 
When  used  regularly,  the  filter  may  become  clogged  with  dust  and  dirt  particles.  The  filter  must  be 
cleaned a minimum of every two weeks (not doing so could invalidate the units’ warranty). Please use 
the following steps:  

 

Remove the filter (it can be found inside the fitted filter frame).  

 

Clean both sides of the filter with the end of a hoover or soapy water no hotter than 40°C. Rinse 
and dry completely before inserting back into the dehumidifier.

 

 

 

 

REPLACING THE HEPA FILTER 

The HEPA filter is not life-long and must be replaced when the colour changes from white to grey (it 
depends on the environment the dehumidifier is being used in, but the HEPA filter will need replacing 
roughly every 3 months). The HEPA filter can be hoovered every so often in order to remove any dust 
or dirt.  

Using a HEPA filter is optional. The dehumidifier can be used without the HEPA filter, this means it will 
just dehumidify the air and not purify it.   

Replacement HEPA filters can be purchased from 

www.meaco.com

 

 

Summary of Contents for 12L Low energy Dehumidifier

Page 1: ...Air Purifier Instruction Manual Meaco 12L and 20L Low Energy Dehumidifier Air Purifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you f...

Page 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Page 3: ...r stored in a non ventilated area then the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by...

Page 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Page 5: ...re the air is cooled below dew point so that the water vapour of the air forms a condensate on the coils which flows into the internal container ready to be poured away The cooled and dried air is hea...

Page 6: ...mentally friendly For this reason we have stopped including continuous drainage hoses in our dehumidifiers to reduce the amount of plastic waste created as most of our customers do not use them If you...

Page 7: ...k and insert it into the spout which drips into the water tank Snip the circular disc on the back of the unit to the bottom right of the filter and push the 12mm hose through the hole securing it to t...

Page 8: ...o clean the inside of the 20L Low Energy water tank the lid needs to be removed via the handle Turn the handle to align the handle grooves with the circular holes on the water tank Gently squeeze both...

Page 9: ...60 55 50 45 40 35 30 CO AP OFF TIMER BUTTON The OFF Timer acts as a countdown timer This can be used if you want the dehumidifier to run for a set number of hours and then switch off Press the OFF Ti...

Page 10: ...n the environment For more information of AP or CO mode see page 13 Once the target humidity level has been reached is more than 3 below the dehumidifier will go to sleep for half an hour and the read...

Page 11: ...AP OFF TIMER BUTTON The OFF Timer acts as a countdown timer This can be used if you want the dehumidifier to run for a set number of hours and then switch off Press the OFF Timer button and then use...

Page 12: ...d its target humidity level This light will be solid it will not flash If the light is flashing it is in defrost mode DEFROST MODE This dehumidifier is equipped with an automatic defrosting system Whe...

Page 13: ...ir Purification mode To achieve this mode keep pressing the DOWN arrow until AP appears on the display In this mode the dehumidifier will not collect any water but all the air that goes through the de...

Page 14: ...e landing or hallway If you have more of a problem in one area of your house flat place the dehumidifier closer to that area Leave all the interior doors open and keep the windows closed Moisture in t...

Page 15: ...y two weeks not doing so could invalidate the units warranty Please use the following steps Remove the filter it can be found inside the fitted filter frame Clean both sides of the filter with the end...

Page 16: ...ollowing steps 1 Remove the plug from the socket and empty the water tank Allow the water tank and the dehumidifier to dry completely this can take a couple of days 2 Clean the filter and store the de...

Page 17: ...and 80 rh Louvre Yes manual Yes automatic Air flow nominal 90m hour 160m hour Auto restart Yes Yes Filter Yes and an optional HEPA filter Yes and an optional HEPA filter Noise level at one metre Maxim...

Page 18: ...ondition the dehumidifier becomes inefficient and little water will be collected The air filter is dirty and blocked The air filter must be cleaned If the air filter is beyond cleaning it must be repl...

Page 19: ...owing out warm air The dried air is passed over heating coils before it is blown into the room as part of the dehumidification process This is normal a dehumidifier is not an air cooler Dehumidifier i...