Designation
Function
Comment
9...28V
Supply voltage
with polarity reversal
protection
U/I Out
Negative bridge excitation (AGND)
9...28V or 2V over the
maximum output signal;
Scale
Control lead for Scale or "ENTER"
High Active; duration as
for GSV-6CPU
Tare
Control lead for "Tare" or "UP"
High Active; duration as
for GSV-6CPU
TEDS
Input for TEDS
as GSV-6CPU
Functions
The functions can be adjusted using the "Tare" and "Scale" control cables.
A simulator to configure the GSV-6 via control cables is also available via
http://www.me-systeme.de/click/click.php
Function
Settings
Analogue output "Type"
0...10V,
±
10V, 0...5V,
±
5V, 4...20mA, 0...20mA
Analogue output "Offset"
0%, 10%, 12.5%, 20%, 25%, 30%, 37.5%, 40%, 50%
Example: an offset of 50% with an analogue output 0...10V shifts
the zero point at 0 mV/V to 5V. With an output of 4...20mA, the
zero point is shifted to 12mA with an offset of 50%. The input
sensitivity is shown at all times on the remaining "End Value -
Offset" area.
Data frequency in Hz
(Updating of measurement
values at the analogue output
or interface)
0.1, 0.2, 0.5, 1, 2, 10, 20, 50, 100, 200, 500, 1k, 2k, 5k, 10k, 20k,
25k;
The smallest data frequency at the output is 10Hz. At levels below
10Hz, a second-order IIR filter is used.
Input sensitivity in mV/V
0.1, 0.2, 0.3. 0.4, 0.5, 1, 2, 3, 4, 5, 8 (standard mode)
0.1, 0.2, 0.3, 0.4, 0.5, 1, 2, 3, 4, 5, 8 (high-res. mode)
In high-res. mode the physical measuring range is restricted,
which means there is less "reserve" available for a zero
adjustment with the Tare function.
Available physical measuring ranges: 8 mV/V, 4 mV/V, 2 mV/V, 1
mV/V
The input sensitivity can also be set to 5-digit precision using the
Tare and Scale cables in the ClickRClackR menu ("seamless").
Adjust autoscale level
The autoscale level allows the output signal to be defined as a %
of the end value, which is shown by implementing "Scale" with the
current weight limit. Default setting: 100% (a weight limit of 100%
is expected).
The autoscale level can be adjusted in stages, from 5% within the
range 0 to 100%. When "0%" is set, the autoscale function is