Assembling and connecting
the wireless flush-mount
switch
The wireless flush-mount switch is
suitable only for use in dry indoor
spaces. The wireless flush-mount switch
must be kept stationary and installed
and operated in a suitable flush-
mount or surface mount socket, or
in a different casing that is suitable.
ATTENTION!
The installation must be undertaken
only once the device is disconnected
and volt-free.
•
In order to ensure that, disconnect from the
electric mains supply line by switching off or
unscrewing the corresponding fuse.
•
Also switch off the corresponding fault-
current circuit breaker, so that the mains
supply line is separated from the mains
voltage on all poles. Safeguard it from an
unauthorized switch-on and ensure that the
corresponding mains supply line remains
switched off.
Please heed the safety instructions
before connecting the wireless
flush-mount switch.
ATTENTION!
The “mini” wireless flush-mount
dimmer is not suitable for the two-way
or intermediate switch circuits!
The special two-wire design of the “mini”
wireless flush-mount switch ensures that no
neutral conductor is necessary. Both existing
cables (phase “L” and the switched phase
“L L”) of the existing off-switch will suffice.
The “mini” wireless flush-mount switch in
the two-wire design is therefore ideal
for adding a wireless switch function to a
conventional wall switch. That means that
the existing wall switch can be retained
Summary of Contents for CUVEO CR-UPMS300
Page 1: ...FUNK EINBAUSCHALTER MINI CR UPMS300 BETRIEBSANLEITUNG...
Page 2: ...FUNK EINBAUSCHALTER MINI CR UPMS300 02 DE...
Page 3: ...PE N L 4 1 2 3 03 DE...
Page 14: ...MINI WIRELESS FLUSH MOUNT SWITCH CR UPMS300 14 EN...
Page 15: ...PE N L 4 1 2 3 15 EN...
Page 25: ...25 EN...
Page 26: ...INTERRUPTEUR ENCASTRABLE RADIO MINI CR UPMS300 26 FR...
Page 27: ...PE N L 4 1 2 3 27 FR...
Page 38: ...DRAADLOZE INBOUWSCHAKELAAR MINI CR UPMS300 38 NL...
Page 39: ...PE N L 4 1 2 3 39 NL...
Page 50: ...50...
Page 51: ...51...