![MDV iThermo4All User Manual Download Page 17](http://html1.mh-extra.com/html/mdv/ithermo4all/ithermo4all_user-manual_1757526017.webp)
the device will turn on for temperatures higher than the
one set.
•
The "Web Connection" button allows you to activate /
deactivate the sending of the operating data of the ther-
mostat to the website. Disabling the button will NOT be
possible to control the thermostat via the website (see
the chapter "The Website”).
•
The "Advanced" button allows you to set special param-
eters of the thermostat: the field delta (thermic differen-
tial) allows you to set in tenth of degrees (from 0 to 9)
the range of activation / deactivation. Example: if we set
value to 0 and the set temperature is 20°C, winter mode
shutdown will occur at 20.1 ° C and the activation at
19.9 ° C. If we set the field to 2, the shutdown will be at
20.3°C and the activation at 19.7°C. Sensitivity (High,
Medium, Low) allows you to set the number of readings
that the thermostat uses to calculate the temperature.
The thermostat does a temperature reading approxi-
mately every 10 seconds, and displays the value based
on the average temperature.
High sensitivity: average of 4 readings.
Medium sensitivity: average of 8 readings.
Low sensitivity: average of 16 readings.
The field “Correction” allows you to modify the value
of the temperature detected by the thermostat, in case is
not equal to the actual temperature for particular envi-
ronmental conditions, or to calibrate in a more precise