www.marketdirect.com.au
Ph: 1300 494 494
52
Problem
Possible Cause
Remedy
Pump not working
(no noise)
No power from control panel
Check circuit breaker
Flat Battery
Charge battery
Faulty pressure switch
Replace pump, Contact dealer for replacement
Bad electrical connection
Check connections with multimeter or test light
Pump working
but no water flow
Airlock in water lines
Turn on tap and hold finger over nozzle for 5
seconds and release. Repeat several times. If this
fails, fill water tank and use mains pressure to
pressurize tank
Water tank is empty
Fill water tank
Kinked hose
Check hoses ensuring none are fouled
Damaged / worn pump diaphragm
Repair or replace pump
Problem
Possible Cause
Remedy
Cooker not igniting
Gas bottle empty
Fill gas bottle
Gas bottle not turned on
Turn on valve on gas bottle
Gas hose on cooker not connected
Check bayonet is securely connected into
receiver
Regulator blocked
Check regulator is not blocked with dirt, wasps
nests etc
Kinked hose
Check hose is not twisted and kinked
Remember that first use after connecting gas will take a little while for the gas to purge the line to the cooktop.
Hold the control knob down for up to 4 minutes
Trouble Shooting
Water
Gas
Summary of Contents for XT12E 2021
Page 36: ...www marketdirect com au Ph 1300 494 494 32 ...
Page 52: ...www marketdirect com au Ph 1300 494 494 48 Fig 1 ...
Page 65: ...www marketdirect com au Ph 1300 494 494 61 Trip Name Date Km Start Km Finish Cumulative Km ...
Page 67: ...www marketdirect com au Ph 1300 494 494 63 Hub Assembly ...
Page 68: ...www marketdirect com au Ph 1300 494 494 64 Trailing Arm Bushes ...
Page 92: ...www marketdirect com au Ph 1300 494 494 88 Video Tutorials COMING SOON ...