Trouble Shooting
When entering fault mode, the display will flash the LED lights to indicate the fault code. This will be indicated by:
2 long flashes of 2 seconds followed by a sequence of flashes with a 0.5 second interval. The number of quick flashes
indicates the fault code on the table below.
Times of
flashes of LED
Cause of trouble
1
Failure of second start
2
Termination of the third time of combustion
3
Power voltage out of specified range
4
Combustion chamber temperature too high during self-check period
6
Broken circuit or short-circuit of temperature sensor
7
Broken circuit or short-circuit of fuel pump
8
Broken circuit, short-circuit, or rotation clogging of fan motor
9
Broken circuit or short-circuit of glow plug
10
Ambient temperature over high before starting or furnace body temperature
over high during heating process
11
Broken circuit or short-circuit of overheating sensor
12
Broken circuit or short-circuit of control switch
13
Maintenance reminder: More than 800 hours of work time
14
Failure of controller
Summary of Contents for XT16HR ISLAND 2021
Page 38: ...www marketdirect com au Ph 1300 494 494 34...
Page 46: ...www marketdirect com au Ph 1300 494 494 42 12 Volt Wiring Diagram Main Circuit...
Page 47: ...www marketdirect com au Ph 1300 494 494 43 Wiring Diagram Switch Panel...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Schematic...
Page 68: ...www marketdirect com au Ph 1300 494 494 64 Trouble Shooting Electrical...
Page 78: ...www marketdirect com au Ph 1300 494 494 74 Trip Name Date Km Start Km Finish Cumulative Km...
Page 81: ...www marketdirect com au Ph 1300 494 494 77 Hub Assembly...
Page 82: ...www marketdirect com au Ph 1300 494 494 78 Trailing Arm Bushes...