1
Ov
er-v
oltage or Under-v
oltage
V
oltage is be
yond nominal v
oltage ±25%
Check y
our power supply b
y multimeter
. If below nominal v
oltage 25%, pls recharge or change
battery
. If abo
ve nominal v
oltage 25%, please change y
our power supply
.
2
Ov
er-heating
1. Blockage in the air inlet or air outlet
Clear the air inlet or air outlet if there is a blockage.
2. Blockage in the e
xhaust pipe
Clean the e
xhaust pipe if there is a block.
3
Fault of flame sensor
1. Incorrect connection
Check all the plug-in connectors and ensure lead is not loose. Rectify if required.
2. Short circuit or open circuit of lead
Check for a short circuit or open circuit of lead of flame sensor with a multimeter
. Fix it or
replace as necessary
.
3. Damage of motor
Check continuity of flame sensor b
y multimeter
. If it fails replace it
4
Fault of motor
1. Incorrect connection
Check all the plugs for secure connection and rectify if necessary
2. Short circuit or open circuit of lead
Check whether there is short circuit or open circuit of motor lead b
y multimeter
. If y
es, please
fix it or replace it.
3. Damage of motor
Check whether motor rotation is normal after energized detection. If not, please replace it.
5
Fault of glow plug
1. Incorrect connection
Check whether all the plug connections are secure and rectify where necessary
2. Short circuit or open circuit of lead
Check whether there is short circuit or open circuit of motor lead b
y multimeter
. If y
es, please
fix it or replace it.
3. Damage of glow plug
Check glow plug’s resistance between two leads. If it is not between 1-4 ohms, pls replace it
6
Fault of o
ver-heating sensor
1. Incorrect connection
Check all the plugs for secure connection and rectify if necessary
2. Short circuit or open circuit of lead
Check whether there is short circuit or open circuit of lead b
y multimeter
. If y
es, please fix it or
replace it.
3. Damage of o
ver-heating sensor
Check whether there is a damage of o
ver-heating sensor
. If y
es, please replace it.
7
Fault of fuel metering pump
1. Incorrect connection
Check all the plugs for secure connection and rectify if necessary
2. Short circuit or open circuit of lead
Check whether there is short circuit or open circuit of lead with multimeter
. If y
es, please fix it
or replace it.
3. Damage of fuel metering pump
Check fuel pump
’s resistance between two leads. If it is not between 15-25 ohms, pls replace it
8
Fault of temper
ature sensor
1. Short circuit or open circuit of lead
Check whether there is short circuit or open circuit of lead b
y multimeter
. If y
es, please fix it or
replace it.
2. Damage of temper
ature sensor
Check whether there is a damage of temper
ature sensor
. If y
es, please replace it.
9
Ignition failure
1. No fuel in the container
Check whether there is fuel or enough fuel in tank
2. F
uel pipe block
ed or brok
en
Check whether the pipe is block
ed b
y impurity and each connection is intact. if so, please repair
or replace it.
3. F
uel pipe block
ed b
y fuel condensation
If there is fuel condensation, please use fuel which is suitable for low temper
ature to replace
pre
vious fuel.
4. Blockage in e
xhaust pipe
Please clean the e
xhaust pipe if there is a block.
5. Fault of controller
Replace the controller
10
Flame failure
1. Not enough fuel in container
Pro
vide enough fuel
2. Fault of ignition sensor
Troubleshooting or replace it.
Trouble shooting and fault guide
Summary of Contents for XT16HR ISLAND 2021
Page 38: ...www marketdirect com au Ph 1300 494 494 34...
Page 46: ...www marketdirect com au Ph 1300 494 494 42 12 Volt Wiring Diagram Main Circuit...
Page 47: ...www marketdirect com au Ph 1300 494 494 43 Wiring Diagram Switch Panel...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Schematic...
Page 68: ...www marketdirect com au Ph 1300 494 494 64 Trouble Shooting Electrical...
Page 78: ...www marketdirect com au Ph 1300 494 494 74 Trip Name Date Km Start Km Finish Cumulative Km...
Page 81: ...www marketdirect com au Ph 1300 494 494 77 Hub Assembly...
Page 82: ...www marketdirect com au Ph 1300 494 494 78 Trailing Arm Bushes...