www.marketdirect.com.au
Ph: 1300 494 494
32
Diesel Heater
Pre January 2019 Model up to Vin # LC003710
Heater Control
The control switch panel is used to control the unit functions.
1.
Ventilation mode indicator
2.
Heating/Combustion mode indicator
3.
Heating selector button
4.
Stop button
5.
Ventilation selector button
6.
Temperature selector
Important tips about operation:
•
Do safety check before initial starting of the heater. Check all components for secure fit (tighten screws
where necessary). Carry out a visual check whether fuel system, combustion air system, exhaust system is
unobstructed.
•
Normal operation of heater at altitudes up to 1500 m.
•
Heater can be used for short periods at altitude 1500 - 3000m. Over 3000m, the heater must be customized.
•
During the initial start-up of the heater, odours can be produced for a short time. This is fully normal during the
first few minutes of operation and does not indicate a malfunction in the heater.
•
During the initial start-up of the heater, there may be an alarm caused by ignition failure. This is because fuel is
needed to fill in fuel pipe. Restarting heater nominally should rectify this.
Operating instructions
•
Pressing ventilation button on switch will activate the fan only. This will operate without combustion to
ventilate the area.
•
Pressing the heating selector button will start the combustion process and begin heating mode. Combustion
and ventilation lamps light up simultaneously.
•
As a fault occurs during operation of the heater, combustion indicator light flashes to indicate cause of the
malfunction.
•
Pressing the stop button. The heater stops working (combustion or ventilation). After delayed stop, the light
goes out.
•
Temperature regulating knob is used for setting temperature for the heater’s automatic temperature control.
Adjustment range is 10-30 ° C.
•
Switch between ventilation and combustion state is possible.
•
When switching off from heating mode, allow the unit to run on ventilation mode until the unit cools. This will
prevent fumes.
Switching on
•
Press heating mode button on control switch, combustion and ventilation indicating light lights up. Then,
heater starts running with glow plug working and fan running at low speed.
•
If there is still too much residual heat in the heat exchanger from when the heater was last used, firstly only the
fan starts up (cold blowing). Once the residual heat has been cleared, the heater starts.
Heating process
•
After approx. 60 seconds the fuel supply starts and the fuel / air mixture in the combustion chamber ignites.
•
After the flame sensor has detected the flame, the glow plug is switched off after approx. 90 sec. The heater
has reached the “POWER” stage gradually (maximum fuel quantity, maximum fan speed).
Summary of Contents for FORBES 13 2021
Page 25: ...www marketdirect com au Ph 1300 494 494 21 Electrical Diagrams Switch Panel...
Page 26: ...www marketdirect com au Ph 1300 494 494 22 Main Circuit...
Page 43: ...www marketdirect com au Ph 1300 494 494 39...
Page 48: ...www marketdirect com au Ph 1300 494 494 44 Hub Assembly...
Page 49: ...www marketdirect com au Ph 1300 494 494 45 Trailing Arm Bushes...
Page 70: ...www marketdirect com au Ph 1300 494 494 66 Trip Name Date Km Start Km Finish Cumulative Km...