Gas & Appliance Safety
Gas Certification
Your Caravan has been supplied gas tested and certified. Any additions or alterations to the gas system must be
performed by an authorised person and will require re-certification and testing. Also note any alterations may affect
your warranty on both the system and appliances.
General Safety
•
Your Caravan may have a number of gas safety labels affixed throughout containing important information. All
instructions are to be followed and the labels shall not be removed for any reason.
•
Make sure to close appliance valves before opening the cylinder valves.
•
Where readily accessible, check connections at the appliances, regulator, hoses and cylinders periodically for
leaks with soapy water (or an equivalent) – this should be done every time a cylinder is changed
or at least annually.
CAUTION – the ammonia present in some soaps and detergents can react with brass fittings and cause such
fittings to crack after a short period of time. Therefore, caution should be exercised when using soap solutions
on brass fittings and all connections should be rinsed thoroughly with fresh water as soon as possible after the
application of
the soap solution.
•
Never use a match or flame when checking leaks.
•
Never use cooking appliances for comfort heating.
•
In the event of a fire, immediately close cylinder valve if safe to do so.
•
Appliances must not be altered without the authorisation of the manufacturer.
•
In the event of an accidental gas leak, close cylinder valve and ventilate the area using a safe method until the
air is clear.
•
Flexible hoses are used between the LP Gas Cylinder and regulator as well as between your slide-out kitchen
cooker (if fitted) and the gas bayonet. These flexible hoses are easily accessible and shall be inspected regularly
by a competent person.
Gas Cylinder Safety
•
LP Gas cylinders have a 10-year lifespan between inspection and re-certification. Always use gas cylinders
that are within their compliance date.
•
For drawbar mounted cylinders (if applicable), orient the cylinder relief valves of both cylinders discharge
away from both the trailer and towing vehicle as shown.
•
For gas cylinders stored in a dedicated LP Gas Locker ensure the locker is kept closed at all times unless
changing or operating the cylinders.
•
Close cylinder valves when appliances are not in use or while refuelling is in progress.
•
Ensure cylinder valves are closed to prevent the unintended release of gas from a cylinder.
Discharge
Discharge
45˚
45˚
Cylinder
relief valve
Summary of Contents for FORBES 13 2021
Page 25: ...www marketdirect com au Ph 1300 494 494 21 Electrical Diagrams Switch Panel...
Page 26: ...www marketdirect com au Ph 1300 494 494 22 Main Circuit...
Page 43: ...www marketdirect com au Ph 1300 494 494 39...
Page 48: ...www marketdirect com au Ph 1300 494 494 44 Hub Assembly...
Page 49: ...www marketdirect com au Ph 1300 494 494 45 Trailing Arm Bushes...
Page 70: ...www marketdirect com au Ph 1300 494 494 66 Trip Name Date Km Start Km Finish Cumulative Km...