16
RD6
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV
Description
S
L/S
Range
Note
1
Lokadresse
3
L
1
–
127
only if CV14 = 0
7
Software version
–
–
read only (10 = 1.0)
7
Decoder reset functions
3 ranges available
11
16
33
basic settings (CV 1,11-13,17-19)
programming lock (CV 15/16)
function- & Switch outputs (CV 20-49)
8
Manufacturer ID
160
–
read only
7+8
Register programming mode
Reg8 = CV-Address
Reg7 = CV-Value
CV 7/8 don’t changes his real va
lue
CV 8 write first with cv-number, then CV 7
write with value or read
(e.g.: CV 49 should have 3)
➔
CV 8 = 49, CV 7 = 3 writing
9
SDF-House time min in minute
3
S
1
–
255
minimal time for reload rate
10
SDF- House time max in minute
15
S
1
–
255
maximum time for reload rate
12
Random generator
0
W
0
–
255
Add value to the CV for function
0 = deactive
+1 = A1, +2 = A2, +4 = A3, +8 = A4, +16 = A5,
+32 = A6
13
Automatic protocoll detection
0
LS
0/1
0 = automatic detection
1 = only DCC (recommended for multi-
protocol command stations)
14
Locomotive/switch control
1
LS
0/1
0 = locomotive control
1 = turnout control
15
Programming lock (key)
75
S
0
–
255
to lock only change this value
16
Programming lock (lock)
75
S
0
–
255
changes in CV 16 will change CV 15
17
SDF time for function
10
S
0
–
255
time base (10 ms / value)
18
Switch address calculation
0
S
0/1
0 = Switch adress like norm
1 = Switch adress like Roco, Fleischmann
19 Restore last position after restart
or voltage drop
0
LS
0
–
255
Add value to the CV for function
0 = deactive
+1 = A1, +2 = A2, +4 = A3, +8 = A4, +16 = A5,
+32 = A6