CSP
−
902RFM207E
−
1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD900 (902 Configuration with PW 207E)
FAA Approved
Reissue 2
Original
3
−
15
3
−
8.
FIRE EMERGENCIES
CABIN FIRE/SMOKE
Indications:
Smoke and fume accumulation in the cabin.
Conditions:
On ground
Procedures:
Engine control switches
OFF
Passengers/crew
EVACUATE
Rotor brake (if installed)
APPLY
Power switch
OFF
Conditions:
In flight
Procedures:
Cabin heat
OFF (if source of smoke is the
cabin heat duct)
Fresh air vents
OPEN
AC/VENT switch
VENT LOW OR VENT HIGH
NOTE
:
If crew station and/or passenger compartment gaspers appear to be the source
of smoke and or fumes, the AC/VENT switch should remain OFF or be returned
to OFF.
Cockpit door vents
OPEN
Land immediately
After landing:
Engine control switches
OFF
Rotor brake (if installed)
APPLY
Power switch
OFF
Passengers/crew
EVACUATE