CSP-HE/HS-1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD 500
(Models 369HE/HS/HM
)
Revision 6
3-13
FAA Approved
Conditions:
In flight
Procedures:
F
Land immediately
POWER ON APPROACH AND LANDING
WITHOUT DELAY
F
Air vents
VENTILATE CABIN AS NECESSARY
F
Twistgrip
CUTOFF-AS SOON AS HELICOPTER IS ON
GROUND
F
BATTERY/EXT PWR switch
OFF
F
Passengers/crew
EVACUATE
If unable to land immediately and fire source can be identified:
F
Malfunctioning system
OFF
F
Fire extinguisher
USE AS NECESSARY
F
Cabin
VENTILATE
F
Land
AS SOON AS POSSIBLE
If fire source is unknown:
F
Cabin heat
OFF
F
GEN
OFF
F
All electrical circuits
(not required for safety of flight)
OFF
F
Cabin
VENTILATE
F
Land
AS SOON AS POSSIBLE