Valvola di Sicurezza 3 bar CE
PN10, TMAX 110°C
A4
Attenzione temperatura acqua!
T 110°C
A4
41
9-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction prohibited
DISCHARGE VALVE 3 bar
The safety valve that can be inspected is found on the right side of the stove, under the pump. A high resistance pipe is connected, as
per standard, to the safety discharge to drain the water until the bracket of the hydraulic connections. From that point, it is MANDATORY
to connect a rubber hose that can withstand a temperature of 110°C (not supplied) and that reaches the outside for any water outlet.
The manufacturer of the appliance is not liable for any flooding caused by the safety valves being triggered if these
have not been joined properly to the outside of the product and to a proper collection and evacuation system.
A4 System outlet 1/4” M
Connection to water drain valve
(as per standard on stove)