Performance Data
Model : M5ACV 030CR / 055CR - Cooling
62
WATER
AVAIL.
PUMP
PUMP
COOL
POWER RUNNING COOL
POWER RUNNING COOL
POWER RUNNING COOL
POWER RUNNING FLOW
HEAD
INPUT
INPUT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
RATE
PRESS.
POWER
AMP
kW
kW
A
kW
kW
A
kW
kW
A
kW
kW
A
m
3
/hr
kPa
W
A
4
9.79
3.81
14.1
9.69
3.97
14.7
9.13
4.62
17.1
8.69
4.90
18.1
1.26
82
194
0.9
5
10.03
3.84
14.2
9.94
4.01
14.8
9.36
4.67
17.2
8.91
4.95
18.3
1.30
82
196
0.9
6
10.27
3.89
14.4
10.17
4.04
14.9
9.56
4.71
17.4
9.09
4.99
18.4
1.32
79
197
0.9
7
10.47
3.91
14.4
10.38
4.08
15.1
9.78
4.76
17.6
9.32
5.05
18.7
1.36
76
199
0.9
8
10.96
3.97
14.7
10.84
4.14
15.3
10.14
4.81
17.8
9.61
5.09
18.8
1.39
76
201
0.9
9
11.29
4.01
14.8
11.21
4.18
15.4
10.38
4.86
17.9
9.82
5.14
19.0
1.43
74
203
0.9
10
11.86
4.07
15.0
11.73
4.23
15.6
10.93
4.90
18.1
10.34
5.18
19.1
1.49
73
206
0.9
4
13.09
4.06
8.6
12.76
4.31
9.1
11.30
5.11
10.8
10.56
5.59
11.9
1.58
170
211
0.9
5
15.04
4.18
8.9
14.80
4.43
9.4
13.62
5.24
11.1
12.95
5.72
12.1
1.97
155
231
1.0
6
16.36
4.29
9.1
16.21
4.54
9.6
15.37
5.35
11.3
14.80
5.83
12.4
2.28
140
248
1.1
7
17.99
4.42
9.4
17.85
4.68
9.9
17.01
5.49
11.7
16.40
5.98
12.7
2.52
127
260
1.1
8
18.99
4.50
9.6
18.87
4.76
10.1
18.09
5.56
11.8
17.47
6.05
12.8
2.69
118
269
1.2
9
20.31
4.61
9.8
20.12
4.86
10.3
19.05
5.67
12.0
18.28
6.16
13.1
2.78
112
274
1.2
10
20.99
4.71
10.0
20.75
4.96
10.5
19.44
5.76
12.2
18.56
6.25
13.3
2.80
111
275
1.2
WATER
AVAIL.
PUMP
PUMP
COOL
POWER RUNNING COOL
POWER RUNNING COOL
POWER RUNNING COOL
POWER RUNNING FLOW
HEAD
INPUT
INPUT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
RATE
PRESS.
POWER
AMP
kW
kW
A
kW
kW
A
kW
kW
A
kW
kW
A
m
3
/hr
kPa
W
A
4
8.35
5.03
18.6
7.98
5.14
19.0
7.35
5.22
25.9
6.14
5.27
19.5
1.26
82
194
0.9
5
8.56
5.09
18.8
8.17
5.19
19.2
7.53
5.27
26.1
6.29
5.31
19.6
1.30
82
196
0.9
6
8.73
5.13
19.0
8.34
5.23
19.3
7.69
5.31
26.3
6.42
5.34
19.8
1.32
79
197
0.9
7
8.96
5.20
19.2
8.56
5.30
19.6
7.91
5.37
26.6
6.60
5.39
19.9
1.36
76
199
0.9
8
9.22
5.23
19.3
8.79
5.32
19.7
8.09
5.39
26.7
6.75
5.42
20.0
1.39
76
201
0.9
9
9.45
5.27
19.5
8.97
5.37
19.8
8.33
5.43
26.9
6.98
5.45
20.1
1.43
74
203
0.9
10
9.90
5.31
19.6
9.42
5.40
20.0
8.64
5.46
27.1
7.16
5.48
20.3
1.49
73
206
0.9
4
10.11
5.91
12.5
9.71
6.23
13.2
9.20
6.94
14.9
8.56
7.51
15.9
1.58
170
211
0.9
5
12.50
6.04
12.8
12.07
6.37
13.5
11.44
7.08
15.2
10.43
7.66
16.2
1.97
155
231
1.0
6
14.39
6.15
13.1
13.96
6.48
13.7
13.26
7.18
15.5
11.98
7.77
16.5
2.28
140
248
1.1
7
15.95
6.31
13.4
15.46
6.64
14.1
14.65
7.35
15.8
13.12
7.94
16.9
2.52
127
260
1.1
8
17.00
6.37
13.5
16.48
6.70
14.2
15.62
7.40
15.9
13.93
7.99
17.0
2.69
118
269
1.2
9
17.72
6.48
13.8
17.13
6.81
14.5
16.15
7.51
16.2
14.34
8.10
17.2
2.78
112
274
1.2
10
17.94
6.57
13.9
17.30
6.89
14.6
16.27
7.59
16.4
14.41
8.19
17.4
2.80
111
275
1.2
WATER
AVAIL.
PUMP
PUMP
COOL
POWER RUNNING COOL
POWER RUNNING FLOW
HEAD
INPUT
INPUT
CAP.
INPUT
CURRENT
CAP.
INPUT
CURRENT
RATE
PRESS.
POWER
AMP
kW
kW
A
kW
kW
A
m
3
/hr
kPa
W
A
4
5.28
5.39
19.9
3.78
5.41
20.0
1.26
82
194
0.9
5
5.42
5.40
19.9
3.89
5.43
20.1
1.30
82
196
0.9
6
5.55
5.42
20.0
4.01
5.45
20.1
1.32
79
197
0.9
7
5.71
5.44
20.1
4.13
5.47
20.2
1.36
76
199
0.9
8
5.84
5.46
20.2
4.24
5.50
20.3
1.39
76
201
0.9
9
5.98
5.47
20.2
4.36
5.52
20.4
1.43
74
203
0.9
10
6.20
5.50
20.3
4.48
5.56
20.5
1.49
73
206
0.9
4
8.19
8.31
17.6
8.15
8.34
17.7
1.58
170
211
0.9
5
9.48
8.46
18.0
9.30
8.49
18.0
1.97
155
231
1.0
6
10.55
8.57
18.2
10.24
8.60
18.3
2.28
140
248
1.1
7
11.36
8.76
18.6
10.98
8.79
18.7
2.52
127
260
1.1
8
11.94
8.80
18.7
11.51
8.83
18.7
2.69
118
269
1.2
9
12.28
8.91
18.9
11.83
8.95
19.0
2.78
112
274
1.2
10
12.38
8.99
19.1
11.95
8.96
19.0
2.80
111
275
1.2
M5ACV055CR
MODEL
M5ACV030CR
MODEL
M5ACV030CR
MODEL
M5ACV030CR
M5ACV055CR
M5ACV055CR
LEAVI
N
G
WAT
ER
T
EM
P (
°C
)
L
EAVI
N
G
WAT
ER
T
EM
P
(°
C
42
46
30
32
AMBIENT TEMPERATURE ON CONDENSOR (°C)
AMBIENT TEMPERATURE ON CONDENSOR (°C)
35
40
L
EAVI
N
G
WAT
ER
T
EM
P
(°
C
19
20
25
AMBIENT TEMPERATURE ON CONDENSOR (°C)
28