IMM AGS-2
67
Current
Imbalance Fault?
Wiring Good?
SCRs OK?
Motor
Winding Short?
All Gate
Pulses Present?
Replace
Control Card
Return
to
Normal
Operation
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Yes
No
No
No
No
Motor Problem?
Repair or
Replace Motor
Contact
Benshaw
For Assistance
Replace
Control Card
Check Jumpers
Parameters
and CTs
Correct Wiring
Replace
Defective
SCRs
Does Problem
Still Exist?
Contact
McQuay
For Assistance
CT Burden
Switches Set
Correctly?
Fuses Blown or
Breaker Tripped?
Replace Fuse
or Reset Breaker
From Previous Page
11
7
12
13
14
12
15