1-16

If any malfunction of the air conditioner unit is noted, immediately switch off the power supply to the unit.
Check the following fault conditions and causes for some simple trouble shooting tips.

TROUBLE SHOOTING

CAUSES / ACTION

- Protection against frequent starting. Wait for 3 to 4

minutes for the compressor to start operating.

- Power failure, or the fuse need to be replaced.

- The power plug is disconnected.

- It is possible that your delay timer has been set incorrectly.

-   If the fault persist after all these verifications, please

contact the air conditioner unit installer.

- The air filter is dirty.

- The doors or windows are open.

- The air suction and discharge are clogged.

- The regulated temperature is not high enough.

- Odors may be caused by cigarettes, smoke particles,

perfume etc. which might have adhered onto the coil.

- This is caused by air humidity after an extended long

period of operation.

- The set temperature is too low, increase the temperature

setting and operate the unit at high fan speed.

- Switch off unit and call dealer.

- Refrigerant fluid flowing into the evaporator coil.

FAULT

1. The compressor does not start operate after 3 minutes

from starting the air conditioner unit.

2. The air conditioner unit does not operate.

3.   The air flow is too low.

4. Discharge air flow has bad odor.

5. Condensation on the front air grille of the indoor unit.

6. Water flowing out from the air conditioner unit.

7. Hissing air flow sound from the air conditioner unit

during operation.

If the fault persists, please call your local dealer / serviceman.

SERVICE AND MAINTENANCE

SERVICE PARTS

MAINTENANCE PROCEDURES

PERIOD

1. Remove any dust adhered on the filter by using a vacuum cleaner or

At least once

    wash in lukewarm water (below 40

o

C) with neutral cleaning detergent.

every 2 weeks.

Indoor air filter

2. Rinse well and dry the filter before placing it back onto the unit.

More frequently if

3. Do not use gasoline, volatile substances or chemical to clean the filter.

necessary.

1. Clean any dirt or dust on the grille or panel by wiping it using soft

At least once

    cloth soaked in lukewarm water (below 40

o

C) with neutral detergent

every 2 weeks.

Indoor unit

    solution.

2. Do not use gasoline, volatile substances or chemical to clean the

More frequently if

    indoor unit.

necessary.

!

 Caution

Do not operate any heating apparatus too close to the air conditioner unit. This may cause
the plastic panel to melt or deform as a result of the excessive heat.

CK20A(1-16)ENG

2/1/01, 10:15 AM

16

Summary of Contents for ACK20A

Page 1: ...CEILING CASSETTE SPLIT TYPE AIR CONDITIONER INSTALLATION MANUAL COVER CK 20A 2 1 01 10 34 AM 3...

Page 2: ...YCK20AR SL20BRK ALC20BRK MLC020BRK YSL20BRK CK25AR ACK25AR MCK025AR YCK25AR SL25BRK ALC25BRK MLC025BRK YSL25BRK CK30AR ACK30AR MCK030AR YCK30AR SL30CR ALC30CR MLC030CR YSL30CR CK40AR ACK40AR MCK040AR...

Page 3: ...not touch the refrigerant piping or any moving parts of the fan motors Confirm that the unit has been switched OFF before installing or servicing the unit IMPORTANT DO NOT INSTALL OR USE THE AIR CONDI...

Page 4: ...g Air Intake Air Discharge Wireless Remote Control Air Discharge Louver Remote Control INSTALLATION DIAGRAM OUTDOOR UNIT Drain Hose Front Panel Air Filter behind the grille Air Discharge Louver Air In...

Page 5: ...door Unit CK20A 25A 30A 40A 50A AR With Wireless Remote Control With Wired Remote Control F H I J G M E C D B A Outdoor Unit SL20B 25B MODEL A B C D E F G H I J K L SL20B 840 492 408 378 330 297 309 6...

Page 6: ...bstacles in path of cool air discharge and warm air return and must allow spreading of air throughout the room near the center of the room Must be provide clearance for the indoor unit from the wall a...

Page 7: ...he installers concerned 620 5 mm Hanging rod 890 0 mm Ceiling board opening Unit size 820 0 mm Unit size 820 0 mm 790 0 mm Hanging rod 890 0 mm Ceiling board opening Unit Confirm the pitch of the hang...

Page 8: ...ol air leakage Connect the LED wire and air swing wire to the indoor unit Indoor Unit Pipe Clamp GOOD BAD Drain Piping Work Drain pipe must be in downward gradient for smooth drainage Avoid installing...

Page 9: ...be considered If the unit comes with ionizer filter optional item make sure to fix the ionizer filter to the air filter before installing the air intake grille Fix the ionizer filter to the air filter...

Page 10: ...VATION M 8 m 8 m 10 m 10 m 10 m MAX NO OF BENDS 10 10 10 10 10 LIQUID PIPE SIZE 1 4 3 8 3 8 3 8 3 8 GAS PIPE SIZE 5 8 5 8 5 8 3 4 3 4 SL SERIES A B C D MIN DISTANCE mm 300 1000 300 500 MSS SERIES A B...

Page 11: ...inside wall of copper tubings Cut the pipe stages by stages advancing the blade of pipe cutter slowly Extra force and a deep cut will cause more distortion of pipe and therefore extra burr Remove bur...

Page 12: ...subject to the type of installation and size of conductors COMP L N N COMP N Interconnection Cable Indoor Unit Terminal Block Outdoor Unit Terminal Block There must be a double pole switch with minim...

Page 13: ...ble Outdoor Unit Terminal Block Heat Pump CK20AR CK25AR MODEL INDOOR CK20AR CK25AR OUTDOOR SL20BRK SL25BRK VOLTAGE RANGE 220 240V 1ph 50Hz POWER INPUT cooling heating W 2225 1940 2937 2435 RATED CURRE...

Page 14: ...ged in vacuuming Charging Before charging the vacuum must be held at 500 microns Hg for at least 15 minutes then break vacuum by charging R 22 refrigerant Operate the unit for 15 minutes and ensure th...

Page 15: ...h the air louver Be sure not to push the sealing material in any farther than about 10 mm INDICATOR LIGHTS Remote Control When there is infrared remote control operating signal the signal receiver on...

Page 16: ...erature STANDARD OPERATION CONDITIONS Cooling Temperature Tso C Tho C Minimum indoor 16 11 temperature Maximum indoor 32 23 temperature Minimum outdoor 16 11 temperature Maximum outdoor 43 26 temperat...

Page 17: ...ter 3 minutes from starting the air conditioner unit 2 The air conditioner unit does not operate 3 The air flow is too low 4 Discharge air flow has bad odor 5 Condensation on the front air grille of t...

Page 18: ...dans ce manuel Im Falle einer widerspr chlichenAuslegung der vorliegendenAnleitung bzw einer ihrer bersetzungen gilt dieAusf hrung in Englisch nderungen von Design und technischen Merkmalen der in di...

Reviews: