Remove Heater
Shift the carriage control valve to neutral and then the selector
valve down to the fusion position. Move the carriage to the left
just enough to remove the heater.
TX00465-9-14-94
Heat Pipe and Fitting
Move selector valve to the center position, if pressure during the
heat cycle differs from fusion pressure. Move the carriage to the
right to bring the fitting in contact with the heater and the heater
in contact with the main. The carriage control valve lever must
be positioned in the right hand position to maintain pressure.
Establish proper melt pattern as specified by the material
supplier.
TX00464-9-14-94
Special Operations
- Saddle Fusion Procedure
PH00402-9-21-94
5 - 4
PH00404-9-21-94
Prepare Heater
Heater is Not Explosion Proof. Operation of
heater in a hazardous environment without
necessary safety precautions will result in explosion
and death.
If operating in a hazardous environment, heater
should be brought up to temperature in a safe
environment, then unplugged before entering the
hazardous atmosphere for fusion.
Use a clean non-synthetic cloth to clean the saddle fusion heater
adapter surfaces.
Verify heater temperature by noting the reading on the dial
thermometer.
Check the heater temperature and install heater between the
fitting and main. Assure proper line-up.
TX00463-9-16-94
PH00389-9-21-94
PH00417-11-1-94
Summary of Contents for TracStar 28