QLT 180/1000-1, 1002-1, & 1001-1 Installation Manual
© 2002-03, IMI Cornelius Inc.
- 1 -
Publication Number: 85312001INS
UNIT SPECIFICATIONS
NAMEPLATE DATA:
Model QLT180/1000–1, 115VAC, 9.43 amps, 1 phase 60 hertz, 6.25 oz. (177g) R–134a refrigerant.
Model QLT180/1002–1, 230 VAC, 5 amps, 1 phase, 50 hertz, 6.25 oz. (177g) R–134a refrigerant.
Model QLT180/1001–1, 220VAC, 5 amps, 1 phase, 60 hertz, 6.25 oz. (177g) R–134a refrigerant.
TEST PRESSURE: High side 250 psi (17.01 bar). Low side 140 psi (9.5 bar).
CONCENTRATE STORAGE: One 1.6 gallon (6 liter) disposable pouch.
CLEARANCE RECOMMENDED: 12” (30.48 cm) on top and 4” (10.16 cm) required in back for air circu-
lation if sides are blocked off. If sides are open only 2” (5.08 cm) are required in back. Space between
bottom of the unit and counter top cannot be obstructed in foot print area.
ELECTRICAL CONNECTION: 6 ft. long (1.83 m) power cord with 3–prong plug attached to dispenser
(115 volt models). Export voltages (230 volt, 50 hertz) shipping to Europe have Std. Euro–plug. All others
have line cord less plug.
POWER SUPPLY: 15 amps at 120 volts, 10 amps at 230 volts, or 10 amps at 220 volts.
WATER CONNECTION: 3/8 in. (.95 cm) SAE male flare fitting on dispenser.
WATER SUPPLY REQUIREMENTS: 100 psi (7 bar) maximum static pressure. 40 psi (2.8 bar) minimum
dynamic pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 ounces (88.7 ml) per
second water flow.