Notes

The Beer Check has a rechargeable battery that is not replaceable 

in the field. Remember to 

keep it charged. 

(Battery-

shaped indicator in upper 

left corner of the screen.)

The operating principles 

of the Beer Check are 

such that it will only be 

accurate when the gases 

in the mix are the only ones present. For example if you were to 

sample the gas from a beer keg the gas would also contain water 

vapor and alcohol vapor making the results inaccurate.
The screen which is also a touch pad works best when tapped with 

a fingernail or plastic stylus.
The Beer Check will turn itself off when left untouched for 5 

minutes. To turn it off manually touch the Main icon and then the 

Off icon.
The Beer Check cannot be calibrated in the field. It is ideal to keep a 

known, accurate calibration gas to test the unit from time to time, 

ensuring the accuracy of your readings.
The Beer Check is affected by altitude, if you will be using it above 

4,000 please discuss this with 

McDantim

.

If there is more than one blend, repeat the process for a keg on the 

other blend.

If you have any questions or need assistance, contact us 

Monday through Friday, 8:00 a.m. - 5:00 p.m. Mountain time.

888-735-5607

Summary of Contents for Beer Check

Page 1: ...r to 5 to 10 psi Disconnect the gas supply from the coupler and attach to the adaptor Turn on the Beer Check by touching the screen It will open in the CO2 N2 mode within 10 seconds Turn on the gas to the Beer Check Take a reading The most accurate reading is when the numbers first stop flashing for more than a few seconds Turn off and disconnect the Beer Check The Beer Check will turn itself off ...

Page 2: ... the nut to the adaptor use the washer Coupled turned ON Uncoupled turned OFF Gas Line Nut 0 011 Ø Hole here limits flow 1 to 2 scfh 5 to 10 psig 7 8 14 Thread Same thread as keg couplers attach gas line nut here 1 4 hose barb attach Beer Check tube here 0 022 Ø Hole here allows flow of 8 to 15 scfh 5 to 10 psig ...

Page 3: ...pad works best when tapped with a fingernail or plastic stylus The Beer Check will turn itself off when left untouched for 5 minutes To turn it off manually touch the Main icon and then the Off icon The Beer Check cannot be calibrated in the field It is ideal to keep a known accurate calibration gas to test the unit from time to time ensuring the accuracy of your readings The Beer Check is affecte...

Page 4: ...ntim Inc will extend the following warranty to the original purchaser of the Beer Check MGA 01 MV019 If the unit becomes inoperable within the first year from the date of delivery for any reason other than unusual or abusive use or handling McDantim Inc will at its option have the unit repaired or replaced If a claim is made after one year from date of delivery to the original purchaser and the un...

Reviews: