background image

McCall Refrigeration / 81 West Holly Street / Parsons, TN 38363

Phone (731) 847-5570 / Fax (731) 847-9012 / 1-888-REACH-IN (1-888-732-2446) / www.mccallrefrigeration.com

January 2007 / Printed in U.S.A.

6

McCall Heated Holding Cabinets shall have:

Stainless steel front, doors and floor. Self-closing all metal doors with welded and
polished corners. Cam-lift hinges with concealed light switches. Adjustable
doorstops. Exterior digital thermometer (1000 series) dial thermometer (2000-
4000 series). Sized and balanced systems maintains temperature range of 140˚F-
170˚F. Chrome-plated door handles with security lock. Stainless steel pilasters
(1000 series) & aluminum pilasters (2000-4000 series) adjustable on 1" centers.
Three epoxy coated shelves per section. 6" adjustable legs. Master Power Switch.
49 cubic ft. capacity. Dimensions: Width = 55"/Height = 84.5"

 

Pass Thru 

(see Pass-Thru Heated Holding Cabinet spec sheet)

Hinged glass doors 

Half height doors.

Heavy-duty 6 inch casters 

(cord connected models only).

Finished back.

Tray slides 

Alarm systems.

300 series stainless steel shelves.

extra epoxy coated shelves.

Dial Thermometer

Sliding glass doors

OPTIONS

Description

DIMENSIONS

Two

Section 

Net Capacity:

49 cu.ft.

Width:

55"

Depth: cabinet only

31.19"

Depth: over hardware - reach-in

34.81"

Depth: over hardware - pass-thru

38.44"

Depth: door open 90° - reach-in

57.81"

Depth: door open 90° - pass-thru

84.19"

Height: including 6" legs

84.5"

Net Door Opening: width

21.25"

Net Door Opening:

height - half doors

27"

Net Door Opening:

height - full doors

58"

Adjustable Shelves:

6

Shipping Weight

Model 1-1045H

3-4045H

2-2045H

690 lbs.
610 lbs.
540 lbs.

Two Section

Voltage (60 cycle single phase):

208/240

Heater Wattage:

2630/3500

Total Amperage (fans & heaters):

13.4/15.4

ELECTRICAL

55

78.5

84.5

Model 1-1045H

Model 2-2045H

Model 4-4045H

H

EATED

H

OLDING

C

ABINETS

(2 S

ECTION

)

Certain options and accessories may affect UL/NSF
listing and electrical requirements.

Specifications subject to change without notice.

TOP VIEW

FRONT VIEW

Bidding Specifications

34.19

57.81

POWER
CONNECTION

AIA #

16032