McCain ATC eX NEMA Controller – User Manual
7
Version 1.0
other end. Ensure a reliable connection by properly latching the spring latches onto the connector’s
latching blocks.
For port’s pin assignments see appendix D.
2.4.1.7 Port 2, SP-4, Terminal PC or General Purpose port
Port 2 is a general purpose port but it is primarily used for connecting a terminal and to perform data
transfer between the controller and an external computer.
It is located on front panel on a DB-9 male connector with jackscrews and it is labeled as Port 2. RTS,
CTS and DCD lines are not available on this port.
This port uses RS-232 asynchronous serial communications with a software selectable speed from
1.2Kbps to 115.2Kbps, with a default speed of 115.2Kbps.
For port’s pin assignments see appendix D.
2.4.1.8 SP-5 Port
SP-5 Port is a general purpose port; it is located on front panel on a DB-9 male connector with jackscrews
and it is marked as SP-5.
This port uses RS-232 asynchronous serial communications with software selectable speed from 1.2Kbps
to 115.2Kbps, with a default speed of 38.4Kbps.
For port’s pin assignments see appendix D.
2.4.1.9 SP-8 Port
SP-8
Port is a general purpose port; it is located on front panel on a DB-9 male connector with jackscrews
and it is marked as SP-8. This port uses RS-232 synchronous serial communications with software
selectable speed from 19.2Kbps to 614.4Kbps, with a default speed of 153.6Kbps.
For port’s pin assignments see appendix D.
2.4.1.10
Communications Modem Slot
SP-1 and SP-2 are general purpose ports and they are available on the communications slot at DIN96
connector.
The ports’ differential communications signals are used depending on the board plugged into the
communications slot (2070-7A, 2070-7B, 2070-6A, 2070-6B, etc); if the board is an asynchronous
communications board (such 2070-7A/6A/6B) the speed is software selectable from 1.2kBbps to
115.5Kbps, if the board is a synchronous communications board (2070-7B) the speed is software
selectable from 19.2Kbps to 614.4Kbps.
For port’s pin assignments see appendix D.
2.4.1.11
A2 Connector
This circular connector provides the AC connection (Line, neutral and chassis ground) and also the fault
monitor (FM) output. This connector is intended to be used when the controller is installed into NEMA
TS2 Type 1 cabinets.
Summary of Contents for ATC eX NEMA
Page 2: ...This page was intentionally left blank...
Page 3: ...Version REVISIONS Rev By Date Comments 1 0 GRubio 11 20 2010 Initial release...
Page 8: ...iv This page was intentionally left blank...
Page 33: ...McCain ATC eX NEMA Controller User Manual 25 Version 1 0 APPENDICES...
Page 35: ...SCHEMATIC TITLE M69945 PCB HOST BOARD ATC NEMA...
Page 52: ...SCHEMATIC TITLE M66279 PCB MODEM BOARD ATC NEMA...
Page 56: ...SCHEMATIC TITLE M66449 PCB CONN BOX ATC NEMA STD MCCAIN...
Page 65: ...McCain ATC NEMA Controller User Manual Version 1 0 DRAWING TITLE M66670 ATC NEMA CONTROLLER...
Page 69: ...DRAWING TITLE M66671 CONNECTOR BOX ATC NEMA STD MCCAIN...
Page 95: ...BILL OF MATERIALS DESCRIPTION M66671 ATC NEMA CONNECTORS BOX STD MCCAIN...
Page 99: ...BILL OF MATERIALS DESCRIPTION M44646 ATC NEMA TRACONEX COMPATIBLE BOX...