background image

 

6

BRIDGED (MONO) OPERATION 

 
Connect as follows :  HOT 

-   

Channel A Hot   

 

 

 

 

 

 

 

 

COLD  -   

Channel B Hot   

 
Leave both COLD connections open circuit, they are internally joined. 
 

             NOTE

:  The load impedances change when operating in the bridged mode. (See Load/Power section  

 

 

 

below.) 

 
LOAD/POWER SWITCH   2 ohm/4 ohm 
 
In  the  4  ohm  position,  the  amplifier  supply  voltages  are  set  up  for  loads  of  4  ohms  and  above.  Lower 
impedance loads can be connected but the internal current limit circuit could cause clipping, and unless 
the signal is very dynamic, the internal temperature rise will automatically reduce the supply voltages and 
set  the  amplifier  to  the  2  ohm  position.  In  the  2  ohm  position,  the  supply  voltages  are  reduced  and  the 
level (overload) indicators and limiters are re-referenced accordingly. 
 

When operating in bridged mode, the minimum impedances are doubled, i.e. for 4 ohm loads use 
the 2 ohm position and for 8 ohm loads use the 4 ohm position. The minimum load in bridged mode 
is 4 ohms. 

 

OPERATION 

 
SWITCHING ON 

 

When the amplifier is switched on, the outputs will be muted and the controller will check for any faults. 
It then goes through a power up routine and finally connects the speakers to the output stages and fades up 
the signal to the level at which the amplifier was previously set. 
 
PANEL CONTROLS AND INDICATORS 

 

Level controls 

 

These are continuous rotary encoders which provide fine adjustment (3 turns from min. to max.). When 
adjusted,  the  level indicators  change  to  level  control position  indicators  and  thus  the height  of  the  LED 
column shows the level position. After a second or so the LED column changes back to monitor the signal 
level. This function can be changed internally via the programming switches on the control PCB. (See the 
Internal Configuration section.) 

 

Mute Switches 

 

These are self explanatory, and require one push to mute the signal and one to un-mute  - toggle action. 
The LEDs indicate their status and when "un-muting" the signal is ramped (faded) up. 

 

Link Switch 

 

This is also a toggle action switch, the LED above indicates its status. When ON, the two level controls 
are linked together and either control will adjust both channels to the same level. The controls track very 
accurately  and  operate  as  stereo  attenuators.  The  limiters  are  also linked. When OFF,  the  level  controls 
and limiters operate separately. 

 

Level Indicators 

 

These are peak reading meters which show the signal headroom before clipping. The 0dB LED is set at 
approximately 1/2dB below clipping. They are referenced to the supply voltages and automatically adjust 
when the supply changes. When the level controls are adjusted, the level indicators change function and 
show the level control position. They return to their normal function after the level has been set. 

Summary of Contents for MC450

Page 1: ...MC450 MC650 MC750 OPERATING INSTRUCTIONS MC 2 AUDIO Ltd Units 6 7 Kingsgate Heathpark Industrial Estate HONITON Devon EX14 1YG England Tel 0 1404 44633 Fax 0 1404 44660 www mc2 audio co uk ...

Page 2: ...Inputs 5 Outputs 5 Rear panel switches 6 OPERATION Switching on 6 Level controls 6 Mute switches 6 Link switch 6 Level indicator 7 Limiters 7 Temperature control 7 Fault indicators 8 2 ohm LED 8 INTERNAL CONFIGURATION SWITCHES 8 FAULTS FUSES 8 REMOTE CONTROL OPTION 9 REMOTE CONTROL SET UP INSTRUCTIONS 10 ...

Page 3: ... ohms Dimensions mm all 2U 88x482x381 88x480x410 88x480x410 Weight 20 4 kgs 22 kgs 22 kgs Power requirement 230 VAC 230 VAC 230 VAC 7 0 amps max 9 0 amps max 10 0 amps max or 120 VAC 120 VAC 120 VAC 14 0 amps max 18 0 amps max 20 0 amps max Product compliance to EC Directives This product conforms to the relevant Directives Regulations and Standards for electronic and associated apparatus The equi...

Page 4: ...or safety reasons THE EARTH LEAD SHOULD NOT BE DISCONNECTED IN ANY CIRCUMSTANCE If ground loops are encountered consult the section on input connections later in this manual TO PREVENT THE LIKELIHOOD OF SHOCK OR FIRE HAZARD DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE TO AVOID ELECTRICAL SHOCK DO NOT REMOVE COVERS REFER ALL SERVICING TO QUALIFIED PERSONNEL INSTALLATION MECHANICAL To ensure that this...

Page 5: ...N1 is connected directly to the chassis mains earth If ground loops mains hum are encountered remove the screen connection from the other end of the cable and leave it open circuit If problems persist consult your dealer supplier DO NOT TAMPER WITH OR ALTER ANY GROUND EARTH CONNECTIONS INSIDE THE AMPLIFIER BRIDGED OPERATION In Bridged mode input A is fed to both channels Channel B will be out of p...

Page 6: ...et PANEL CONTROLS AND INDICATORS Level controls These are continuous rotary encoders which provide fine adjustment 3 turns from min to max When adjusted the level indicators change to level control position indicators and thus the height of the LED column shows the level position After a second or so the LED column changes back to monitor the signal level This function can be changed internally vi...

Page 7: ...evel controls are manually turned back up or until the amplifier is switched off NOTE All levels are referenced to the clipping point of the amplifier and not an actual output voltage or power level If the mains power drops or increases then the limit threshold will also change thus maintaining maximum output level Temperature Control If the heat sinks get excessively hot the controller will autom...

Page 8: ...columns will always show the signal level and will not change to show the level control position when the level controls are adjusted Sw 4 5 These select the threshold level as follows Sw4 Sw5 ON ON Just below clipping point ON OFF 1dB below clipping point OFF ON 2dB below clipping point OFF OFF 3dB below clipping point Sw 6 Sw 7 operate together they determine the operating mode and release time ...

Page 9: ...gether and controlled all at the same time within that group The front panel controls on the amplifiers can be locked out so that they can only be controlled from the computer This allows the system to be set up to the client s requirements and then made secure against manual interference Two levels of security are available on the management control system through the use of passwords which permi...

Page 10: ...either end of the cable and connected as follows PIN 2 hot positive PIN 3 cold PIN 5 screen Configuring the PC 1 Launch Amplifier Explorer program can be downloaded from www mc2 mc2 audio co uk 2 Click on the Tools menu and select Serial link setup Then SET OPERATING SYSTEM e g WIN98 SET COM PORT NUMBER SET PORT ADDRESS This happens automatically Set up is now complete Each amplifier has its own i...

Reviews: