Installation and use 

SOLID CONTROL MCK 2200 

4.1.2 

Number of total plants 

(REF. O6)

 

The number of total plants is displayed by pressing the "SELECT" key (ref. F) when 
the arrow indicator appears in line with the "n° of total plants" symbol. Contrary to the 
previous totaliser, this data cannot be reset. 
 

4.1.3 

Working pressure (ref. O7

It is the value read by the pressure transducer (optional) mounted in the atomiser. It 
is displayed when the arrow indicator appears in line with the word "bar". 
 

4.1.4 

Distributed litres (ref. O8

To  display  the  number  of  distributed  litres,  press  the  "SELECT"  key  (ref.  F)  by 
positioning the arrow in line with the "distributed litres" symbol. 
This function can only be used by using the flowmeter, which must be mounted in such 
a way that there are no return circuits in the tank, downstream from this. To reset this 
value,  when  it  is  shown  on  the  display,  keep  the  "SELECT"  key  pressed  until  "0" 
appears on the display. 
For  the  litres  to  be  counted  correctly,  the  constant  "i"  must  be  set  correctly  (see 
paragraph ...). 
 

4.1.5 

Litres left (ref. O9

The outermost vertical segments at the top of the display indicate the function status 
of the sonar sensors. 
When  the  machine  passes  in  front  of  the  plant,  the  sonar  detects  it  and  sends  an 
electrical signal to the computer, which will turn on  these segments ("O1" for the left 
sonar and "O4" for the right sonar). They will remain on for as long as the sonar/s send 
the signal. 
 

4.1.6 

Sensor status (ref. O1 and O4) 

The outermost vertical segments at the top of the display indicate the function status 
of the sonar sensors. 
When  the  machine  passes  in  front  of  the  plant,  the  sonar  detects  it  and  sends  an 
electrical signal to the computer, which will turn on these segments ("O1" for the left 
sonar and "O4" for the right sonar). They will remain on for as long as the sonar/s send 
the signal. 
 
 

Summary of Contents for MCK 2200

Page 1: ...DPA SOLID CONTROL MCK 2200 COMPUTER FOR SPRAYERS INSTRUCTIONS FOR USE NR ST2621 EN REV 3 EN...

Page 2: ...O ITALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code ST2621 EN Issued July 2013 Edition October 2021 MC elettronica S r l is not obli...

Page 3: ...3 Working pressure ref O7 9 4 1 4 Distributed litres ref O8 9 4 1 5 Litres left ref O9 9 4 1 6 Sensor status ref O1 and O4 9 4 1 7 Solenoid valve status ref O2 and O3 10 4 1 8 Working hours 10 4 2 IZ...

Page 4: ...ted by the Customer before starting the mass production The electronic board of the MCK 2200 computer is treated with silicone resin to increase its resistance to possible infiltration of humidity or...

Page 5: ...SELECT RESET key for display indications and totalisers reset G General AUTO MAN key with green LED H PROG key for constants programming I Right START STOP key with red LED L key to decrease the valu...

Page 6: ...3C Status of the left sensor ON OFF IN PNP NO 2C Status of the right solenoid valve ON OFF OUT Vb 8A Status of the left solenoid valve ON OFF OUT Vb 8C Programming parameters Working hours General sol...

Page 7: ...en printed polyester B Self extinguishing ABS box closing black frame C Self extinguishing ABS grey container D Connector for signals and power supply E Fastening knobs F Self extinguishing ABS grey s...

Page 8: ...or receive new settings The function of the individual parts is explained below 4 1 Display The display can be show the following values 4 1 1 Number of partial plants REF O5 The partial plants are c...

Page 9: ...this To reset this value when it is shown on the display keep the SELECT key pressed until 0 appears on the display For the litres to be counted correctly the constant i must be set correctly see para...

Page 10: ...oid valves can be switched one at a time from the automatic operating status to the manual operating status Simply press one of the two special keys ref B and N and the solenoid valves will switch to...

Page 11: ...setting some constants described in the following paragraph N B Only in the case of the full opt art 4494 MCK 2200 model and during work out of the programming mode can an output be controlled by usin...

Page 12: ...crements of 1 can be reset by pressing the RESET key ref F for 3 SECONDS while the number of partial plants is shown on the display ref O5 4 7 3 Total plants totaliser 0 to 99999 increments of 1 canno...

Page 13: ...eous switch of the two sections to automatic mode the following key will be used ref E AUTO MAN GENERAL The enabling of this setting is indicated by the relative green LED going on This key ref E has...

Page 14: ...and that of the plants partial and total takes place in the same way as the automatic mode Even in this case the key ref G has priority over the status of the two sections when the following is press...

Page 15: ...15 CAUTION DO NOT WASH USING A POWER WASHER WITH PRESSURE JET WARNING THIS PRODUCT CONTAINS TIN AND LEAD IT MUST BE DISPOSED OF AT THE END OF ITS LIFE CYCLE AT THE DESIGNATED DISPOSAL FACILITIES OR DE...

Page 16: ...Printed in Italy Electronic equipment for agriculture www mcelettronica it...

Reviews: